0600 | MEDAR STATUS ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in M mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0601 | MEDAR DIAGNO- SIS ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0602 | MEDAR VERSION ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0603 | MEDAR REVISION ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0604 | MEDAR MODE CHANGE ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0605 | MEDAR SCHED- ULE TRANSMIT ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0606 | MEDAR ERROR 1 | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0607 | MEDAR ERROR 2 | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0608 | MEDAR WELDER TYPE MISMATCH | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0609 | MEDAR PARAME- TER ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0610 | MEDAR STEPPER TRANSMIT ERROR | MADER timer error | Refer to the instruction manual for the MEDAR function. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0700 | VERIFY ERROR (EX IO ALLOC FILE) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then set the IO module. | ||||||||||||||||||||||||||||||||||||
Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0710 | LADDER INITIAL- IZE ERROR | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0720 | LADDER PRO- GRAM ERROR | 1 | An error was found in the relay No. specifi- cation. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | An error was found in the register No. spec- ification. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | An incorrect instruc- tion was set. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Output register is used redundantly. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Output relay is used redundantly. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Unconnected relay exists. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | The STR instructions are overused. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | The AND-STR in- structions are over- used. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
9 | A syntax error was found in the CNT in- struction. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
10 | The head of the block starts with an instruc- tion other than the STR instruction. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
11 | Excessive machine codes | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
12 | The last instruction is not the END instruc- tion. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
13 | An error was found in the PART instruction. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
14 | An error was found in the GOUT instruction. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
15 | The No. of operand is incorrect. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
16 | The constant value is incorrect. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
17 | The step capacity ex- ceeds the memory capacity. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
18 | The number of opera- tion instructions ex- ceed the permissible value. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
19 | A syntax error was found in the CNT in- struction or TMR in- struction. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
20 | A syntax error was found in the JMP-LA- BEL instructions. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
21 | The label of JMP des- tination does not ex- ist. | Data error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0730 | COMMUNICATION ERROR (SKS-SERIAL) | 0 | Welder power serial I/ F task cannot be cre- ated. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
1 | Incorrect values are set for the communi- cation frame number with the welder pow- er. | Setting error | (1)Check the following setting. ∙The number of communication frames for Welder power serial communication (RS262) | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Incorrect values are set for the number of the sending bytes per frame with the welder power. | Setting error | (1)Check the following setting. ∙The number of the sending bytes for Welder power serial com- munication (RS262) | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Incorrect values are set for the number of the receiving bytes per frame with the welder power. | Setting error | (1)Check the following setting. ∙The number of the receiving bytes for Welder power serial com- munication (RS262) | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
10 | The binary sema- phore to start up event for Welder pow- er serial I/F task can- not be created. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
11 | The event resource for Welder power seri- al I/F task cannot be created | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
12 | The completion notifi- cation mail of Welder power serial I/F task cannot be created. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
13 | Welder power serial I/ F task cannot be cre- ated. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0770 | SAFETY FIELDBUS SET ERR(YCP21) | 1 | Safety slave and standard master are used simultaneously in one channel of the DeviceNet board. | Setting error | (1) Check the following settings. ·Select {SYSTEM} – {SETUP} – {OPTION BOARD} settings in MAINTENANCE mode. Display the slot (channel) that is config- ured with DeviceNet Safety, set to slave mode. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Board that can not be used with DeviceNet Safety is set. | Setting error | (1) Check the following settings. · Insert the SST-DN4-PCU board to the PCI slot to be used in the DeviceNet Safety. Select {SYSTEM} – {SETUP} – {OPTION BOARD]} settings in MAINTENANCE mode, set the DeviceNet Safety. | |||||||||||||||||||||||||||||||||||
SST-DN4-PCU board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the SST-DN4-PCU board. Save the CMOS.BIN before replace the board to be safe. Replace the SST-DN4-PCU board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0771 | SAFETY FIELDBUS SYS ERR(YCP21) | 10000 | The error was detect- ed by the safety field- bus proccess (YCP21). SUB Code shows the error part ofsoftware. | SST-DN4-PCU board failure | In the case of DeviceNet Safety, please check the following. (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the SST-DN4-PCU board. Save the CMOS.BIN before replace the board to be safe. Replace the SST-DN4-PCU board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0772 | DeviceNet Safety RESET REQUEST | Safety reset request was received from the safety PLC in commu- nication. | Operation failure | Turn the power OFF then back ON. | ||||||||||||||||||||||||||||||||||
0790 | MEMORY BAT- TERY WEAK | The YIF01 battery is exhausted. | Connection failure | (1) Check if the battery is correctly connected to CN110/BAT on the YIF01 board. | ||||||||||||||||||||||||||||||||||
Battery failure | (1) Refer to Chapter “Replacing the Battery” in robot controller Maintenance manual (E1102000152XX01* or higher) and replace the battery. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0800 | FILE BACKUP ER- ROR (YCP21 CF) | The management area (FAT) of Com- pact Flash in YCP21 board is damaged. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | ||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0801 | FILE LOAD ERROR (YCP21 CF) | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3000 | PANELBOX.LOG file broken | DATA failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, select the following menu. ∙{SYSTEM} – {DATA REBUILD} | |||||||||||||||||||||||||||||||||||
Compact Flash failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the Compact Flash. Save the CMOS.BIN before replace the board to be safe. Replace the Compact Flash, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0802 | FILE I/O ERROR (YCP21 CF) | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0803 | FILE ERROR | An error occurred during the parameter of Manipulator Model (mecha.rom) loading. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0804 | DATA ACCESS ER- ROR(VARIABLE AREA) | other | Select the following menu in MAINTENANCE mode and execute {DATA REBUILD} operation. ·{SYSTEM} – {DATA REBUILD} Even if you perform the above operation, the variable data won’t be deleted. | |||||||||||||||||||||||||||||||||||
0810 | TOYOPUC ALLOC DEF ERROR | 1 | An error was found in the input/output direc- tion data of allocation configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3 | In the output side set- ting of allocation con- figuration data, the specified R-register start No. for the TOYOPUC ex- ceeds the R-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | In the output side set- ting of allocation con- figuration data, the set number to use the input side R-register of the TOYOPUC ex- ceeds the R-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | In the output side set- ting of allocation con- figuration data, the set number to use the M-register of concur- rent I/O exceeds the M-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | An error was found in the type set for output direction of allocation configuration data. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
9 | An error was found in the type set for input direction of allocation configuration data. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
10 | An error was found in the type specified for system data of alloca- tion configuration da- ta. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
12 | An error was found in the specified number of registers which are used by the system data “CURR.POS. (PULSE)” of alloca- tion configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
14 | An error was found in the specified number of registers which are used by the system data “CURR.POS. (XYZ)” of allocation configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
16 | An error was found in the specified number of registers which are used by the system data “WELDING IN- FO.” of allocation configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
18 | An error was found in the specified number of registers which are used by the system data “TASK INFO.” of allocation configura- tion. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
20 | An error was found in the specified number of registers which are used by the system data “EXECUTE PROGRAM INFO.” of allocation configura- tion. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
22 | An error was found in the specified number of registers which are used by the system data “INST. MES- SAGE” of allocation configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
23 | An error was found in the specified number of registers for “Alarm/Error/Mes- sage” in the system data of Allocation set- ting information. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
30 | In the input side set- ting of allocation con- figuration data, the specified R-register start No. for the TOYOPUC exceeds the R-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
31 | In the input side set- ting of allocation con- figuration data, the set number to use the input side R-register of the TOYOPUC ex- ceeds the R-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
32 | In the input side set- ting of allocation con- figuration data, the set number to use the M-register of concur- rent I/O exceeds the M-register limit. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
34 | An error was found in the specified number of registers which are used by the system data “standard time setting data” of allo- cation configuration. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
41 | In the output side set- ting of allocation con- figuration data, some of the TOYOPUC’s R- registers are speci- fied redundantly. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
42 | In the output side set- ting of allocation con- figuration data, some of the M-registers of concurrent I/O are specified redundantly. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
44 | In the input side set- ting of allocation con- figuration data, some of the TOYOPUC’s R- registers are speci- fied redundantly. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
45 | In the input side set- ting of allocation con- figuration data, some of the M-registers of concurrent I/O are specified redundantly. | Setting error | (1) Check the following settings. ∙Allocation configuration for the TOYOPUC | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙The PCI connector of the TOYOPUC board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0831 | FORCE SENSOR COMMUNICATION ERROR | 1000 | +channel×100 +factor: 0 send complete error 1 receive time out 2 receive break letter 3 framing error 4 parity error 5 over run error 6 receive length error 7 no STX control let- ter 8 no ETB control let- ter 9 BCC error 10 sequence number error 11 sensor detection error | Hardware failure | (1) After checking the following two terms, turn the power OFF then back ON. ·the connection status ·the sensor type (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
0900 | WATCHDOG TIM- ER ERROR(YIF01 board) | A Watchdog timeout was detected in the YIF01 board. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | ||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0901 | WATCHDOG TIM- ER ER- ROR(YCP02#1) | A Watchdog timeout was detected in the YCP02 #1 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0902 | WATCHDOG TIM- ER ER- ROR(YCP02#2) | A Watchdog timeout was detected in the YCP02 #2 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0903 | WATCHDOG TIM- ER ER- ROR(YCP02#3) | A Watchdog timeout was detected in the YCP02 #3 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0904 | WATCHDOG TIM- ER ER- ROR(YCP02#4) | A Watchdog timeout was detected in the YCP02 #4 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0905 | WATCHDOG TIM- ER ER- ROR(YCP02#5) | A Watchdog timeout was detected in the YCP02 #5 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0906 | WATCHDOG TIM- ER ER- ROR(YCP02#6) | A Watchdog timeout was detected in the YCP02 #6 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0907 | WATCHDOG TIM- ER ER- ROR(YCP02#7) | A Watchdog timeout was detected in the YCP02 #7 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0908 | WATCHDOG TIM- ER ER- ROR(YCP02#8) | A Watchdog timeout was detected in the YCP02 #8 board. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0909 | WATCHDOG TIM- ER ERROR(SF21) | 0 | A Watchdog timeout was detected in the YSF21 board. | YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YSF21 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
1 | YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YSF21 board | ||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0910 | CPU ERROR (YCP21) | 1 | An error was detected in the CPU. | YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0911 | CPU ERROR (YCP02#1) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0912 | CPU ERROR (YCP02#2) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0913 | CPU ERROR (YCP02#3) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0914 | CPU ERROR (YCP02#4) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0915 | CPU ERROR (YCP02#5) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0916 | CPU ERROR (YCP02#6) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0917 | CPU ERROR (YCP02#7) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0918 | CPU ERROR (YCP02#8) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0919 | CPU ERROR(SF21) | 0 | YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YSF21 board | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
1 | YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YSF21 board | ||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0931 | CPU HANG UP ER- ROR(YCP02#1) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0932 | CPU HANG UP ER- ROR(YCP02#2) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0933 | CPU HANG UP ER- ROR(YCP02#3) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0934 | CPU HANG UP ER- ROR(YCP02#4) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0935 | CPU HANG UP ER- ROR(YCP02#5) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0936 | CPU HANG UP ER- ROR(YCP02#6) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0937 | CPU HANG UP ER- ROR(YCP02#7) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0938 | CPU HANG UP ER- ROR(YCP02#8) | An error was detected in the CPU. | Setting error | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0940 | WATCHDOG TIM- ER ERROR(EA- XA#1) | A Watchdog timeout was detected in the EAXA#1 board. | EAXA21 board failure | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0941 | WATCHDOG TIM- ER ERROR(EA- XA#2) | A Watchdog timeout was detected in the EAXA#2 board. | EAXA21 board failure | (1) Check the following settings. ∙Optional board in MAINTENANCE mode | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0942 | WATCHDOG TIM- ER ERROR(EA- XA#3) | A Watchdog timeout was detected in the EAXA#3 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0943 | WATCHDOG TIM- ER ERROR(EA- XA#4) | A Watchdog timeout was detected in the EAXA#4 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0944 | WATCHDOG TIM- ER ERROR(EA- XA#5) | A Watchdog timeout was detected in the EAXA#5 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0945 | WATCHDOG TIM- ER ERROR(EA- XA#6) | A Watchdog timeout was detected in the EAXA#6 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0946 | WATCHDOG TIM- ER ERROR(EA- XA#7) | A Watchdog timeout was detected in the EAXA#7 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0947 | WATCHDOG TIM- ER ERROR(EA- XA#8) | A Watchdog timeout was detected in the EAXA#8 board. | EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0950 | CPU ERROR (EA- XA#1) | An error was detected in the CPU of servo board #1. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0951 | CPU ERROR (EA- XA#2) | An error was detected in the CPU of servo board #2. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0952 | CPU ERROR (EA- XA#3) | An error was detected in the CPU of servo board #3. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0953 | CPU ERROR (EA- XA#4) | An error was detected in the CPU of servo board #4. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0954 | CPU ERROR (EA- XA#5) | An error was detected in the CPU of servo board #5. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0955 | CPU ERROR (EA- XA#6) | An error was detected in the CPU of servo board #6. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0956 | CPU ERROR (EA- XA#7) | An error was detected in the CPU of servo board #7. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0957 | CPU ERROR EA- XA#8) | An error was detected in the CPU of servo board #8. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of EAXA21 board CN509 ∙The cable of EAXA21 board connector CN515/516 ∙The PCI connector of the YIF01 board ∙The cable of YIF01 board connector CN113 | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0970 | CPU ERROR (YSF25#1) | 0 | An error was detected in the CPU of func- tional safety board #1 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #1 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0971 | CPU ERROR (YSF25#2) | 0 | An error was detected in the CPU of func- tional safety board #2 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #2 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0972 | CPU ERROR (YSF25#3) | 0 | An error was detected in the CPU of func- tional safety board #3 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #3 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0973 | CPU ERROR (YSF25#4) | 0 | An error was detected in the CPU of func- tional safety board #4 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #4 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0974 | CPU ERROR (YSF25#5) | 0 | An error was detected in the CPU of func- tional safety board #5 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #5 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0975 | CPU ERROR (YSF25#6) | 0 | An error was detected in the CPU of func- tional safety board #6 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #6 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0976 | CPU ERROR (YSF25#7) | 0 | An error was detected in the CPU of func- tional safety board #7 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #7 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0977 | CPU ERROR (YSF25#8) | 0 | An error was detected in the CPU of func- tional safety board #8 (CPU1). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | An error was detected in the CPU of func- tional safety board #8 (CPU2). | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following connector. ∙CN509 cable of EAXA21 board ∙The cable of EAXA21 board connector CN515/516 ∙CNBX connector of EAXA21board and the YSF25 board ∙The PCI connector of YIF01board ∙The cable of YIF01 board connector CN113 | |||||||||||||||||||||||||||||||||||
YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0980 | WATCHDOG TIM- ER ERROR (YSF25#1) | A Watchdog timeout was detected in the functional safety board #1. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0981 | WATCHDOG TIM- ER ER- ROR(YSF25#2) | A Watchdog timeout was detected in the functional safety board #2. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0982 | WATCHDOG TIM- ER ER- ROR(YSF25#3) | A Watchdog timeout was detected in the functional safety board #3. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0983 | WATCHDOG TIM- ER ER- ROR(YSF25#4) | A Watchdog timeout was detected in the functional safety board #4. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0984 | WATCHDOG TIM- ER ER- ROR(YSF25#5) | A Watchdog timeout was detected in the functional safety board #5. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0985 | WATCHDOG TIM- ER ER- ROR(YSF25#6) | A Watchdog timeout was detected in the functional safety board #6. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0986 | WATCHDOG TIM- ER ER- ROR(YSF25#7) | A Watchdog timeout was detected in the functional safety board #7. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0987 | WATCHDOG TIM- ER ER- ROR(YSF25#8) | A Watchdog timeout was detected in the functional safety board #8. | YSF25 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe. | ||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙EAXA21 board | |||||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
0990 | SYSTEM ERROR (YCP21) | 1 | YCP21board detect the Controller power off signal (Power lost signal) of YIF01 board when the control pow- er turned ON. This alarm may occur, when the control pow- er turned OFF before an online screen is displayed by a pro- gramming pendant, | Execute condition failure | Turn the power OFF after the online window appears on the pro- gramming pendant. | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | YCP21board detect the WATCHDOG TIMER ERROR of YIF01 board when the control power turned ON. | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | YCP21board detect the Servo IF Initialize error of YIF01 board when the control pow- er turned ON. | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | YCP21board detect the IO IF Initialize er- ror of YIF01 board when the control pow- er turned ON. | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Processing time error of the IO processing | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Processing time error of the SV communica- tion, | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | It was detected that AC power supply be- came less than the specified voltage. | Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and insertion of the following cables and connectors. ∙The cable of YPS unit connector CN158/159 ∙The CN5 connector of the YBB21 back board. ∙Cable replace between the YPS unit and the YBB21 back board. | |||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3xxx | YCP21board detect the Servo IF Initialize error of YIF01 board when the control pow- er turned ON. The last three digits indicate an internal error code. | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4xxx | YCP21board detect the IO IF Initialize er- ror of YIF01 board when the control pow- er turned ON. The last three digits indicate an internal error code. | YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YPS unit failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YPS unit. Save the CMOS.BIN before replace the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0991 | SYSTEM ERROR (YCP02#1) | 1 | An error was detected in the CPU of the op- tional YCP02 #1. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0992 | SYSTEM ERROR (YCP02#2) | 1 | An error was detected in the CPU of the op- tional YCP02 #2. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0993 | SYSTEM ERROR (YCP02#3) | 1 | An error was detected in the CPU of the op- tional YCP02 #3. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0994 | SYSTEM ERROR (YCP02#4) | 1 | An error was detected in the CPU of the op- tional YCP02 #4. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0995 | SYSTEM ERROR (YCP02#5) | 1 | An error was detected in the CPU of the op- tional YCP02 #5. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0996 | SYSTEM ERROR (YCP02#6) | 1 | An error was detected in the CPU of the op- tional YCP02 #6. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0997 | SYSTEM ERROR (YCP02#7) | 1 | An error was detected in the CPU of the op- tional YCP02 #7. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0998 | SYSTEM ERROR (YCP02#8) | 1 | An error was detected in the CPU of the op- tional YCP02 #8. | YCP02 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙YCP02 board | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YCP21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the fail- ure YCP21 board to insert it into the new YCP21 board. | |||||||||||||||||||||||||||||||||||||
YIF01 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
0999 | NMI ERROR | Software operation error occurred | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). |