Yaskawa Alarm Codes 4900 – 4999
Yaskawa Alarm Codes 4900 – 4999
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4900 | EXCESSIVE SEG- MENT(SAFETY 2)(SV) | Setting error | (1) Reset the alarm, and then ease the velocity or check whether the posture is singular. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4901 | CUBE/AXIS INTER- FERENCE | Sub Code; Group, ax- is, and interference area number | Setting error | (1) Check the following settings. ∙Perform the teaching again to correct positions for manipula- tors so that the step where the alarm occurred is out of inter- ference area. ∙Change the settings for interference area. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4902 | CUBE INTERFER- ENCE (TCP) | Sub Code; Group and interference area number | Setting error | (1) Check the following settings. ∙Change the step position where the alarm occurred to the area outside the interference area. ∙Modify the interference area setting. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4903 | CUBE INTERFER- ENCE (ENTIRE) | Sub Code; Group, ax- is, and interference area number | Setting error | (1) Check the following settings. ∙Perform the teaching again to correct positions for manipula- tors so that the step where the alarm occurred is out of inter- ference area. ∙Change the settings for interference area. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4904 | CUBE INTERFER- ENCE AREA SET ERR | 0 | Maximum number of the cube interference area exceeds the al- lowable range. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
1 | The number of cube interference area whose monitoring part is “whole” ex- ceeds the limit. | Setting error | Reduce the number of cube interference area whose monitor- ing part is “whole”. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Detect the cube whose interference area are extremely big or small. | Setting error | (1)Among the cube interference areas already values are en- tered, modify as follows. 1.Change the extremely big values to smaller ones. 2.Change the extremely small values to bigger ones. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
3 | Detect the cube inter- ference area whose monitoring part is set to “whole” despite the invalid status of cube arm interference check function. | Setting error | (1) Reset the alarm. (2)If the alarm occurs just after loading the cube interference area setting function, execute the following measures. 1.Among the cube interference areas to be loaded, change the monitoring part setting from “whole” to “control point”. 2.Load the modified cube interference area. 3.Confirm the settings if the alarm occurs again after the load- ing operation. (3) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4905 | INSTRUCTION ER- ROR 1 | 1 | Sub code: SKCHK mode re- lease error | Software operation error occurred | (1) Reset the alarm and decrease the motion speed in JOB. (2) If the alarm occurs again, save the CMOS.BIN in the main- tenance mode and contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Sub code: Robot number error | Setting error | (1) Reset the alarm and change the robot number. (2) If the alarm occurs again, save the CMOS.BIN in the main- tenance mode and contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4906 | MODEL DATA UN- REGISTERED | Sub Code: model file number | Setting error | (1) Reset the alarm and register the model file or change the model file number. | ||||||||||||||||||||||||||||||||||
4907 | MULTIPLE INST EXECUTION ER- ROR | Setting error | (1) Reset the alarm and modify the JOB program. | |||||||||||||||||||||||||||||||||||
4908 | SPEED CONTROL ERROR | 1 | Control group desig- nation error. | Setting error | (1)Reset the alarm. (2)Check the settings for the specified control group number. | |||||||||||||||||||||||||||||||||
2 | Speed control axis designation error. | Setting error | (1)Reset the alarm. (2)Check the settings for the specified speed control axis num- ber. | |||||||||||||||||||||||||||||||||||
3 | Maximum rotation speed over. | Setting error | (1)Reset the alarm. (2)Set the rotation speed that does not exceed the maximum rotation speed. | |||||||||||||||||||||||||||||||||||
4909 | TEST RUN(HIGH ACCURACY) ER- ROR | Operation mistake | Select a sub menu [TEACHING CONDITION SETTING] under main menu [SETUP]. Set “TEST RUN CONTROL” to “NORMAL” to perform TEST RUN operation. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4911 | SAFETY FIELDBUS NOT ESTAB- LISHED | 1 | PROFIsafe communi- cation was not estab- lished to the default time, or communica- tion was disconnect- ed after establishment. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙SF (Group Fault) LED, BF (Bus Fault) LED of CP1616 board is lit or blinking. ∙ SF (Group Fault) LED, BF (Bus Fault) LED of safety PLC board is lit or blinking. (3)If the above problems, there is a possibility that the connec- tion settings of the safety PLC or CP1616 is not successful. Please set again according to the manual. | |||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||||
Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, please check the connection or insertion state of cables connected to the CP1616 board and safety PLC. | |||||||||||||||||||||||||||||||||||||
CP1616 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the CP1616 board. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
10 | CIP Safety communi- cation was not estab- lished to the default time.(sub code is not defined) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
11 | CIP Safety communi- cation was not estab- lished to the default time.(CIP Safety stack is under the Self-diagnosis) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
12 | CIP Safety communi- cation was not estab- lished to the default time.(Waiting for communication es- tablish) | Software configura- tion error occurred | (1) Reset the alarm. (2) If the alarm occurs again, the connection setup of EtherNet/ IP (CPU board) or safety PLC may not be performed normally. Please set up again according to a manual. | |||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
13 | CIP Safety communi- cation was not estab- lished to the default time.(Exception gen- erating under CIP Safety stack self-di- agnosis) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
15 | CIP Safety communi- cation was not estab- lished to the default time.(Abort of CIP Safety stack process- ing) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
18 | CIP Safety communi- cation was not estab- lished to the default time.(Waiting for TUNID configuration) | Software configura- tion error occurred | (1)Reset the alarm. (2)If the alarm occurs again, please carry out the following ac- cording to a manual. – In the case of EtherNet/IP Safety, set up TUNID (combination data of an IP address and Safety Network Number) using RS- NetWorx for EtherNet/IP (setting tool by Rockwell). – In the case of DeviceNet Safety, set up TUNID (combination data of a MAC ID and Safety Network Number) using RSLogix5000 (setting tool by Rockwell). | |||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Connection failure | (1)Reset the alarm. (2)If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4912 | SAFETY FIELDBUS COMM ERROR | 1 | Value of F_Dest_Add do not match. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following F-Pa- rameter settings. ∙The value of F_Dest_Add that is set to the safety PLC and the CP1616 board are the same. | |||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Value of F_Dest_Add is out of range. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following F-Pa- rameter settings. ∙The value of F_Dest_Add that is set to the safety PLC and the CP1616 board is in the range of 1-65534. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Value of F_Src_Add is out of range. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following F-Pa- rameter settings. ∙The value of F_Src_Add that is set to the safety PLC is in the range of 1-65534. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Value of F_WD_Time is 0. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following F-Pa- rameter settings. ∙The value of F_WD_Time that is set to the safety PLC is 1 or more. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Value of F_SIL is in- valid. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙ When setting up the safety the PLC, whether imported into SIEMENS manufactured configuration tool(STEP 7) GSD file of CP1616 board we offer. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Value of F_Par_Ver- sion is invalid. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙ When setting up the safety the PLC, whether imported into SIEMENS manufactured configuration tool(STEP 7) GSD file of CP1616 board we offer. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Value of F_CRC do not match. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙ When setting up the safety the PLC, whether imported into SIEMENS manufactured configuration tool(STEP 7) GSD file of CP1616 board we offer. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Setting the value of the F-Parameter is in- valid. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙ When setting up the safety the PLC, whether imported into SIEMENS manufactured configuration tool(STEP 7) GSD file of CP1616 board we offer. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
10 | Size of F_CRC is in- valid. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙ When setting up the safety the PLC, whether imported into SIEMENS manufactured configuration tool(STEP 7) GSD file of CP1616 board we offer. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
20 | Processing of safety field bus does not start. | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please turn the power OFF then back ON. | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
30 | Communication error of safety field bus oc- curred. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, please check the connection or insertion state of cables connected to the CP1616 board and safety PLC. | |||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
31 | Watchdog time error of safety field bus oc- curred. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, please check the connection or insertion state of cables connected to the CP1616 board and safety PLC. | |||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, please re-power on the safety PLC and the robot controller. | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
32 | Passivated state. | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, you need to release the passiv- ated state. Please release the passivated state by operating the safety program from SIEMENS manufactured configura- tion tool(STEP 7). | |||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
20000 | A communication er- ror (CH1) occurred at connection with the CIP safety. A SUB-Code shows the internal status of a CIP Safety stack. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, you need to release the passiv- ated state. Please release the passivated state by operating the safety program from SIEMENS manufactured configura- tion tool (STEP 7). | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
30000 | A communication er- ror (CH2) occurred at connection with the CIP safety. A SUB-Code shows the internal status of a CIP Safety stack. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, please check the following. ∙In the case of EtherNet/IP Safety, please check the connec- tion or insertion state of cables connected to the „CN104 con- nector of YCP21 board“ and safety PLC. ∙In the case of DeviceNet Safety, please check the connection or insertion state of cables connected to the SST-DN4-PCU (DeviceNet) board and safety PLC. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, you need to release the passiv- ated state. Please release the passivated state by operating the safety program from SIEMENS manufactured configura- tion tool (STEP 7). | |||||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4913 | SUB SEQUENCE TASK CONTR ER- ROR | 1 | Unused A_BANK does not exist in the prereading process- ing of move instruc- tion. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
2 | Unused bank priority does not exist in the prereading process- ing of move instruc- tion. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
5 | A_BANK pointer is not set. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
6 | A_BANK conversion could not be per- formed. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | The specified A_BANK number does not exist. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
20 | An error occurred when system num- ber(MSS) was ob- tained. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
21 | An error occurred in RMS960 system call. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
22 | Undefined interrupt command was re- ceived. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
23 | JOB start condition is not defined. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
24 | An error occurred in instruction prefetch queue operation. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
26 | Intermediate code is not defined. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
29 | Instruction prereading processing has not been completed nor- mally. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
30 | An error occurred in JOB data change. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
31 | The specified se- quence number at job execution start is in- correct. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
32 | The added area for in- terruption command is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
33 | System num- ber(MSS) for interrup- tion command is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
38 | An error occurred at start of twin synchro- nous operation. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
39 | An error occurred when SYNC specifi- cation was reset. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
41 | An error occurred in occupation control group setting in MO- TION section. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
45 | An error occurred in path/trace control. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
47 | An error occurred when waiting for a completion of main system task (JOB) in SYNC specification. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
48 | An attempt was made to execute an instruc- tion that could not be executed at line se- quence execution. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
49 | An error occurred while obtaining the in- struction information. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
80 | An exceptional error occurred in job execu- tion process. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
100 | Main processing command is incorrect in prereading pro- cessing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
101 | SUP-processing command is incorrect in prereading pro- cessing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
102 | Prereading process- ing has not been com- pleted at JOB execution. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
103 | A_BANK conversion has not been com- pleted. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
104 | System num- ber(MSS) is incorrect in prereading pro- cessing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
105 | An error occurred in instruction prefetch queue operation in prereading process- ing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
106 | An error occurred at IES switching in pre- reading processing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
108 | An error occurred in prereading operation process. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
200 | The specified se- quence number is in- correct. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
201 | An attempt was made to execute an instruc- tion that could not be executed in P-PLC program. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4914 | SUB SE- QUENCE(H) TASK CONTR ERROR | 1 | Unused A_BANK does not exist in the prereading process- ing of move instruc- tion. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
2 | Unused bank priority does not exist in the prereading process- ing of move instruc- tion. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
5 | A_BANK pointer is not set. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
6 | A_BANK conversion could not be per- formed. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
7 | The specified A_BANK number does not exist. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
20 | An error occurred when system num- ber(MSS) was ob- tained. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
21 | An error occurred in RMS960 system call. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
22 | Undefined interrupt command was re- ceived. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
23 | Job start condition is not defined. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
24 | An error occurred in instruction prefetch queue operation. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
26 | Intermediate code is not defined. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
29 | Instruction prereading processing has not been completed nor- mally. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
30 | An error occurred in JOB data change. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
31 | The specified se- quence number at JOB execution start is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
32 | The added area for in- terruption command is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
33 | System num- ber(MSS) for interrup- tion command is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
38 | An error occurred at start of twin synchro- nous operation. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
39 | An error occurred when SYNC specifi- cation was reset. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
41 | An error occurred in occupation control group setting in MO- TION section. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
45 | An error occurred in path/trace control. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
47 | An error occurred when waiting for a completion of main system task (JOB) in SYNC specification. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
48 | An attempt was made to execute an instruc- tion that could not be executed at line se- quence execution. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
49 | An error occurred while obtaining the in- struction information. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
80 | An exceptional error occurred in job execu- tion process. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
100 | Main processing command is incorrect in prereading pro- cessing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
101 | Subprocessing com- mand is incorrect in prereading process- ing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
102 | Prereading process- ing has not been com- pleted at JOB execution. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
103 | A_BANK conversion has not been com- pleted. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
104 | System number (MSS) is incorrect in prereading process- ing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
105 | An error occurred in instruction prefetch queue operation in prereading process- ing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
106 | An error occurred at IES switching in pre- reading processing. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
210 | An attempt was made to execute an instruc- tion that could not be executed in SUB se- quence (H) task | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4915 | PathSwitch CON- TROL ERROR | 1 | When PSTRIG in- struction was execut- ed, there was not PLCSTPON instruc- tion or PLCSTPOF in- struction. | Setting error | (1) Reset the alarm. (2) Check whether PLCSTPON instruction and PLCSTPOF in- struction is registered. When unregistered, register PLCST- PON instruction and PLCSTPOF instruction. | |||||||||||||||||||||||||||||||||
2 | When PSTRIG in- struction was execut- ed, P-PLC instruction had not been execut- ed. | Setting error | (1) Reset the alarm. (2) Check whether P-PLC instruction is registered. When un- registered, register P-PLC instruction. (3) When PSTRIG instruction is executed, check P-PLC in- struction is whether it has been executed.If it is not running, please run PSTRIG instruction after P-PLC instruction execu- tion. | |||||||||||||||||||||||||||||||||||
3 | The number of PSTRIG instruction exceeds the limit in the PointPLC pro- gram. | Setting error | (1) Reset the alarm. (2) Please reduce the number that can be set PSTRIG instruc- tion. | |||||||||||||||||||||||||||||||||||
4 | Delay control was not completed. | Setting error | (1) Reset the alarm. (2) Please change the teaching to be able to delay control. | |||||||||||||||||||||||||||||||||||
5 | PSTRIG instruction execution result is err. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
6 | PSTRIG instruction execution result is err. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | PSTRIG instruction execution result is err. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4916 | WRONG JOB EXEC OF DETACHED AXIS | Sub Code: Control group | Setting error | (1) Check the following settings. ∙ [OPTION FUNCTION] – [AXES DETACHMENT] settings in maintenance mode. Cancel the detachment axis setting of the JOB control group. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4917 | WRONG JOB EXEC OF DETACHED AXIS | Sub Code: Control group | Setting error | (1) Check the following settings. ∙ [OPTION FUNCTION] – [AXES DETACHMENT] settings in maintenance mode. Cancel the detachment axis setting of the JOB control group. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4918 | PROFINET SET- TING ERROR | 16 | Device name or IP address has not been set to CP1616 board connected with 1st PCI connector. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please carry out the following ac- cording to a manual. ∙Set the device name and IP address to CP1616 board by us- ing STEP 7 (setting tool by SIEMENS). | |||||||||||||||||||||||||||||||||
CP1616 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the CP1616 board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
17 | Device name or IP address has not been set to CP1616 board connected with 2nd PCI connector. | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, please carry out the following ac- cording to a manual. ∙Set the device name and IP address to CP1616 board by us- ing STEP 7 (setting tool by SIEMENS). | |||||||||||||||||||||||||||||||||||
CP1616 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the CP1616 board | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
116 | Firmware version of CP1616 board con- nected with 1st PCI connector and driver software version does not match | CP1616 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the CP1616 board | |||||||||||||||||||||||||||||||||||
CP1616 board ver- sion failure | (1)Reset the alarm. (2) If the alarm occurs again, please request the update of CP1616 board firmware to your YASKAWA representative. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
117 | Firmware version of CP1616 board con- nected with 2nd PCI connector and driver software version does not match. | CP1616 board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the CP1616 board | |||||||||||||||||||||||||||||||||||
CP1616 board ver- sion failure | (1)Reset the alarm. (2) If the alarm occurs again, please request the update of CP1616 board firmware to your YASKAWA representative. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4919 | SYSTEM JOB(CY- CLIC) EXEC. ER- ROR | 1 | Task ID error | Software operation error occurred | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||
2 | MSS ID error | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
3 | JOB handle error | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4 | RMS error | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
5 | Job type is not SYS- TEM JOB(CYCLIC/ HIGH). | Setting error | (1)Check the following settings. ∙Change the JOB type to „SYSTEM JOB (CYCLIC/HIGH)“. | |||||||||||||||||||||||||||||||||||
6 | The intermediate code of the instruction that is to be executed is incorrect. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
7 | The instruction can- not be executed in the SYSTEM JOB(CY- CLIC/HIGH). | Setting error | (1) Check the following settings. ∙Delete the instruction in which alarm occurred, because the instruction cannot be executed in the SYSTEM JOB (CYCLIC/ HIGH). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
9 | The reinterpretation of the instruction was ordered when execut- ing the instruction. | Software operation error occurred | (1) Reset the alarm, and then try again. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
10 | The SYSTEM JOB (CYCLIC/HIGH) was going to branch to the other JOB. | Setting error | (1) Check the following settings. ∙Delete the instruction in which alarm occurred, because the SYSTEM JOB (CYCLIC/HIGH) cannot branch to the other JOB. | |||||||||||||||||||||||||||||||||||
11 | The execution num- ber of SYSTEM JOB (CYCLIC/HIGH) ex- ceeded a limitation. | Setting error | (1) Check the following settings. ∙Correct the JOB under the current limitation of execution number, because SYSTEM JOB(CYCLIC/HIGH) can no lon- ger be executed. | |||||||||||||||||||||||||||||||||||
12 | The execution of SYSTEM JOB (CY- CLIC/HIGH) was not finished within a time limit. | Setting error | (1) Check the following settings. ∙Reduce the number of items in the SYSTEM JOB(CYCLIC/ HIGH). | |||||||||||||||||||||||||||||||||||
13 | The SYSTEM JOB (CYCLIC/HIGH) was executed in the sys- tem being executed already. | Software operation error occurred | (1) Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
14 | The execution num- ber of items in the SYSTEM JOB (CY- CLIC/HIGH) exceed- ed a limitation. | Setting error | (1)Check the following settings. ∙Reduce the number of items in the SYSTEM JOB(CYCLIC/ HIGH) within the limit number (Initial setting is 300). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4920 | M-SAF CONTAC- TOR SELF CHECK ERR | The meaning of each SUB-Code is as fol- lows: CPU1 1:SFRON1 CPU1 2:SFRON2 CPU1 3:SFRON3 CPU1 4:SFRON4 CPU2 1:SFRON1 CPU2 2:SFRON2 CPU2 3:SFRON3 CPU2 4:SFRON4 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22-CN217 ∙YPU-CN607 ∙Cable continuity between YSF22 board and YPU unit. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
YPU unit failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YPU unit. In a system where a plurality of YPU units are connected, re- place the unit, which is connected to the unit on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4921 | M-SAF STO SELF CHECK ERR | The meaning of each sub code is as fol- lows: CPU1 1:STO1 CPU1 2:STO2 CPU1 3:STO3 CPU1 4:STO4 CPU2 1:STO1 CPU2 2:STO2 CPU2 3:STO3 CPU2 4:STO4 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22-CN217 ∙Cable continuity between YSF22 board and EAXA21 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the EAXA21 board. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4922 | M-SAF GENERAL OUT SELF CHECK ERR | The meaning of each sub code is as fol- lows: CPU1 1:GSOUT1 CPU1 2:GSOUT2 CPU2 1:GSOUT1 CPU2 2:GSOUT2 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YFC22 ∙Cable continuity between YSF22 board and YFC22 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board, which is connected to the GSIN signal on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
YFC22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YFC22 board. In a system where a plurality of YFC22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4923 | YSF24 GENERAL OUT SELF CHECK ERR | The meaning of each sub code is as fol- lows: CPU1 1:XOUT1 CPU1 2:XOUT2 CPU1 3:XOUT3 CPU1 4:XOUT4 CPU1 5:XOUT5 CPU1 6:XOUT6 CPU1 7:XOUT7 CPU1 8:XOUT8 CPU2 1:XOUT1 CPU2 2:XOUT2 CPU2 3:XOUT3 CPU2 4:XOUT4 CPU2 5:XOUT5 CPU2 6:XOUT6 CPU2 7:XOUT7 CPU2 8:XOUT8 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF24 ∙Cable continuity between YSF22 board and YSF24 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YSF24 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF24 board. In a system where a plurality of YSF24 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4924 | M-SAF CONTAC- TOR UNMATCH | The meaning of each sub code is as fol- lows: CPU1 1:SFRON1 CPU1 2:SFRON2 CPU1 3:SFRON3 CPU1 4:SFRON4 CPU2 1:SFRON1 CPU2 2:SFRON2 CPU2 3:SFRON3 CPU2 4:SFRON4 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22-CN217 ∙YPU-CN607 ∙Cable continuity between YSF22 board and YPU unit. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YPU unit failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YPU unit. In a system where a plurality of YPU units are connected, re- place the unit, which is connected to the unit on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4925 | M-SAF STO UN- MATCH | The meaning of each sub code is as fol- lows: CPU1 1:STO1 CPU1 2:STO2 CPU1 3:STO3 CPU1 4:STO4 CPU2 1:STO1 CPU2 2:STO2 CPU2 3:STO3 CPU2 4:STO4 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22-CN217 ∙Cable continuity between YSF22 board and EAXA21 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the EAXA21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4926 | M-SAF GENERAL OUTPUT UN- MATCH | The meaning of each sub code is as fol- lows: CPU1 1:GSOUT1 CPU1 2:GSOUT2 CPU2 1:GSOUT1 CPU2 2:GSOUT2 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YFC22 ∙Cable continuity between YSF22 board and YFC22 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
YFC22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YFC22 board. In a system where a plurality of YFC22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4927 | YSF24 GENERAL OUTPUT UN- MATCH | The meaning of each sub code is as fol- lows: CPU1 1:XOUT1 CPU1 2:XOUT2 CPU1 3:XOUT3 CPU1 4:XOUT4 CPU1 5:XOUT5 CPU1 6:XOUT6 CPU1 7:XOUT7 CPU1 8:XOUT8 CPU2 1:XOUT1 CPU2 2:XOUT2 CPU2 3:XOUT3 CPU2 4:XOUT4 CPU2 5:XOUT5 CPU2 6:XOUT6 CPU2 7:XOUT7 CPU2 8:XOUT8 | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF24 ∙Cable continuity between YSF22 board and YSF24 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YSF24 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF24 board. In a system where a plurality of YSF24 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4928 | M-SAF OUTPUT SIG. SELF CHECK ERR | SUB-Code is the out- put signal number that detected error. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22 ∙Cable continuity between YSF21 board and YSF22 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4929 | M-SAF INPUT SIG. SELF CHECK ERR | SUB-Code is the in- put signal number that detected error. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙YSF22 ∙Cable continuity between YSF21 board and YSF22 board. | ||||||||||||||||||||||||||||||||||
YSF21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF21 board. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YSF22 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the YSF22 board. In a system where a plurality of YSF22 boards are connected, replace the board on which the alarm occurred. | |||||||||||||||||||||||||||||||||||||
Other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4932 | REFERENCE USER FRAME ER- ROR | 1 | reference user frame not set | Setting error | (1) Reset the alarm. (2) Check the following settings. ∙Reference user frame | |||||||||||||||||||||||||||||||||
2 | multiple reference user frame | Setting error | (1) Reset the alarm. (2) Check the following settings. ∙reference user frame | |||||||||||||||||||||||||||||||||||
3 | Incorrect control group designation | Setting error | (1) Reset the alarm. (2) Check the following settings. ∙reference user frame | |||||||||||||||||||||||||||||||||||
4934 | MotoPlus APP. RE- SPONSE ERROR | 0 | The message which was sent the last time has not been re- ceived. | Setting error | (1) Turn the power OFF then back ON. | |||||||||||||||||||||||||||||||||
1 | The message which was sent when the NEXT/BACK/TEST operation was exe- cuted. | Setting error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the following settings. ∙The MotoPlus application has been running. ∙The MotoPlus API mpSendEventAck() that responds to sys- tem software is called in the MotoPlus application. | |||||||||||||||||||||||||||||||||||
2 | The message that was sent when the job was started. | Setting error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the following settings. ∙The MotoPlus application has been running. ∙The MotoPlus API mpSendEventAck() that responds to sys- tem software is called in the MotoPlus application. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3 | The message which was sent from the pendant application. | Setting error | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the following settings. ∙The MotoPlus application has been running. ∙The MotoPlus API mpSendEventAck() that responds to sys- tem software is called in the MotoPlus application. | |||||||||||||||||||||||||||||||||||
4935 | PointPLC EXE- CUTE ERROR | 1 | TAG could not be ex- ecuted on JUMP in- struction in the PointPLC program. | Setting error | (1) Reset the alarm. (2) Delete the TAG of the JUMP instruction which cannot be executed in the PointPLC program. | |||||||||||||||||||||||||||||||||
2 | JUMP instruction or LABEL is wrong in the PointPLC program. | Setting error | (1) Reset the alarm. (2) Modify the JUMP instruction or LABEL in the PointPLC pro- gram. JUMP destination in the PointPLC program will need to be set in the PointPLC program. JUMP destination outside of PointPLC program will need to be set outside PointPLC program. | |||||||||||||||||||||||||||||||||||
3 | TAG could not be ex- ecuted on CLEAR in- struction in the PointPLC program. | Setting error | (1) Reset the alarm. (2) Delete the TAG of the CLEAR instruction which cannot be executed in the PointPLC program. | |||||||||||||||||||||||||||||||||||
4 | TAG could not be ex- ecuted on CALL in- struction in the PointPLC program. | Setting error | (1) Reset the alarm. (2) Delete the TAG of the CALL instruction which cannot be executed in the PointPLC program. | |||||||||||||||||||||||||||||||||||
4936 | LOCAL VARIABLE CONTROL ERROR | 1 | Local variable is used in the PointPLC pro- gram. | Setting error | (1)Reset the alarm. (2) Modify the instruction that uses Local variable in the Point- PLC program. | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4937 | TIMING ADJUST- MENT SETTING ERROR | 1 | Adjustment setting is exceeds the control area of the advance or delay control. | Setting error | Correct the job so that adjustment setting is within the control area. | |||||||||||||||||||||||||||||||||
2 | Timing advance con- trol was impossible. | Setting error | Correct the job so that it does not across the instructions that can not be advance control. | |||||||||||||||||||||||||||||||||||
3 | Timing delay control was inpossible. | Setting error | Correct the job so that it does not across the instructions that can not be delay control. | |||||||||||||||||||||||||||||||||||
4940 | MOTION COM- MAND CODE ER- ROR (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4941 | CANNOT EXE- CUTE MOTION CMD (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4942 | AVERAGING TIME CHANGE ERR (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4943 | AVERAGING TIME ERROR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4944 | POSITION LOOP GAIN ERROR (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4945 | MOTION COM- MAND DATA ER- ROR (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4946 | PG POWER ON IN- COMPLETE (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4947 | SERVO ON MULTI- PLE REQUEST (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4948 | ENCODER ALARM (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4949 | GUN BEND MULTI CORRECT ERR (SV) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the settings for JOBs. | ||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4950 | MOTOR GUN POS. DIFF. OVER (SV) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | (1) Check the settings for JOBs. (2) If this alarm occurs after the SERVO power cycling during work handling process under the condition where the Handling motion continue func- tion is activated (S2C691=1), review the threshold value (S1CxG624 -) as necessary. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4951 | WRONG MOTOR GUN CHANGE AXIS (SV) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the settings for JOBs. | ||||||||||||||||||||||||||||||||||
Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4952 | WRONG MOTOR GUN FILE NO. (SERVO) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the settings for JOBs. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4953 | ENCODER COUNTER DIFF. ERR (SV) | Connection failure | (1) Reset the alarm (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. {Robot axis} ∙Cables between encoders ∙EAXA21-CN508 {External axis} ∙Cables between encoders ∙EAXB21-CN534,535,536 | |||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm. (2) If the alarm occurs again, replace the EAXA21 board. Save the CMOS.BIN before replacing the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4954 | REALTIME STATUS S/R ERROR (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4955 | AVERAGING DATA ERROR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4956 | AVERAGING SUM ERROR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4957 | AVERAGING STA- TUS ERR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4958 | HIGH RESOLU- TION PRM UNDE- FINED (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4959 | WRONG GRP CHANGE AXIS (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4960 | BELT SNAP DE- TECT PRM ERROR (SV) | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4961 | SERIAL ENC OS- CILL DETECTED (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4962 | BRAKE LOCK ER- ROR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4963 | BRAKE RELEASE ERROR (SERVO) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4964 | CONST.SPD MEA- SURE MULTI REQ (SV) | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4965 | DIN SIGNAL SPE- CIFIC. ERROR (SV) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the settings for JOBs. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4966 | DB RESIST NOT INSTALLED (SV) | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙DB resist of CN585 amplifier ∙Short-circuit connector CN585 amplifier ∙Amplifier-CN583 ∙Converter-CN556,CN558 | |||||||||||||||||||||||||||||||||||
DB resist board fail- ure | (1) Reset the alarm. (2) The DB resist may be fired. Replace the DB resist. | |||||||||||||||||||||||||||||||||||||
Module failure (con- verter) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the converter. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4967 | RATED CURRENT AND MAXIMUM CURRENT HIGH RESOLUTION PRM UNDEFINED (SER- VO) | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, contact your YASKAWA repre- sentative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4969 | CONVTR POWER ERR (FREQUEN- CY) (SV) | Sub Code: Signifies the axis in which the alarm occurred | Primary power supply failure | Confirm that appropriate primary voltage is applied to the breaker. Prescribed voltage: 200V (+10% to 15%) | ||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following cables and connectors. ∙EAXA21-CN507,510 ∙EAXB21-CN531,532,533 ∙Converter-CN551,553 ∙EX1SV(External axis servo pack)-CN591,592 | |||||||||||||||||||||||||||||||||||||
Module failure (con- verter) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the converter. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm.(In case of major alarm, turn the power OFF then back ON.) (2) If the alarm occurs again, replace the EAXA21 and EAXB21 boards. Save the CMOS.BIN before replacing the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4970 | CONVTR POWER ERR (PHASE SEQ.)(SV) | Sub Code: Signifies the axis in which the alarm occurred | Primary power supply failure | Confirm that appropriate primary voltage is applied to the breaker. Prescribed voltage: 200V (+10% to 15%) | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following cables and connectors. ∙EAXA21-CN507,510 ∙EAXB21-CN531,532,533 ∙Converter-CN551,553 ∙EX1SV(External axis servo pack)-CN591,592 | |||||||||||||||||||||||||||||||||||||
Module failure (con- verter) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the converter. | |||||||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm.(In case of major alarm, turn the power OFF then back ON.) (2) If the alarm occurs again, replace the EAXA21 and EAXB21 boards. Save the CMOS.BIN before replacing the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4971 | CONVTR POWER ERR (PEAK) (SV) | Primary power supply failure | Confirm that appropriate primary voltage is applied to the breaker. Prescribed voltage: 200V (+10% to 15%) | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following cables and connectors. ∙EAXA21-CN507,510 ∙EAXB21-CN531,532,533 ∙Converter-CN551,553 ∙EX1SV(External axis servo pack)-CN591,592 | |||||||||||||||||||||||||||||||||||||
Module failure (con- verter) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the converter. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm.(In case of major alarm, turn the power OFF then back ON.) (2) If the alarm occurs again, replace the EAXA21 and EAXB21 boards. Save the CMOS.BIN before replacing the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4972 | CONVTR REGEN- ERATE OVERLOAD (SV) | Primary power supply failure | Check the primary voltage for the converter. | |||||||||||||||||||||||||||||||||||
Setting error | Check the following settings; ∙Tool data ∙JOB ∙Workpiece ∙JOB speed ∙Acceleration and deceleration (ACC, DEC) | |||||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following cables and connectors. ∙EAXA21-CN507,510 ∙EAXB21-CN531,532,533 ∙Converter-CN551,553 ∙EX1SV(External axis servo pack)-CN591,592 | |||||||||||||||||||||||||||||||||||||
Module failure (Re- generative resistor) | (1) Disconnect the converter CN557 to check if there is no ca- ble disconnection. (2) If disconnected, replace the regenerative resistor. | |||||||||||||||||||||||||||||||||||||
Module failure (con- verter) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the converter. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
EAXA21 board failure | (1) Reset the alarm.(In case of major alarm, turn the power OFF then back ON.) (2) If the alarm occurs again, replace the EAXA21 and EAXB21 boards. Save the CMOS.BIN before replacing the board to be safe. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4973 | POSITION ERROR (COLLISION DE- TECT) | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Confirm the following settings; ∙Tool information ∙Workpiece | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4974 | POSITION ERROR (START LIFT) | Sub Code: Signifies the axis in which the alarm occurred | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | ||||||||||||||||||||||||||||||||||
4975 | WRONG START LIFT AXIS (SERVO) | Sub Code: Signifies the axis in which the alarm occurred | Software operation error occurred | (1) Reset the alarm. (2) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | ||||||||||||||||||||||||||||||||||
4976 | GUN SEARCH DE- TECT RANGE OVER | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the following settings. ∙Home position of gun axis. ∙”The pulse-stroke converter” in the gun condition file. ∙The value of the wear correction. | ||||||||||||||||||||||||||||||||||
Effect of external force | (1) Check that no objects exist between workpiece and gun. (2) Check the lost tip. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4977 | GUN SEARCH POS ERROR | Sub Code: Signifies the axis in which the alarm occurred | Setting error | Check the following settings. ∙Home position of gun axis. ∙”The pulse-stroke converter” in the gun condition file. ∙The value of the wear correction for movable gun tip. | ||||||||||||||||||||||||||||||||||
Effect of external force | (1)Check the amount of the gap between workpiece position and the teaching position. (2) Check the lost tip for movable gun. | |||||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4978 | UNIV.IN/OUT SIG- NAL BROKEN (SERVO) | 1 | Universal input/output 1 between EAXA21 boards is broken. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, check if the cable is disconnect- ed. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Universal output 1for SV#1 (SV#2) is incon- sistent with Universal input 1 for SV#2(SV#1). | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
3 | Universal output 1for SV#1 (SV#2) is incon- sistent with Universal input 1 for SV#2(SV#1). | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Universal input/output 2 between EAXA21 boards is broken or its connector (CN514) is disconnected. | Connection failure | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, check if the cable is disconnect- ed. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Universal output 2 for SV#1 (SV#2) is incon- sistent with Universal input 2 for SV#2(SV#1). | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
6 | Universal output 2 for SV#1 (SV#2) is incon- sistent with Universal input 2 for SV#2(SV#1). | Setting error | (1) Reset the alarm. (2) If the alarm occurs again, check the connection and insert- ing state of the following cables and connectors. ∙EAXA21-CN514 (3) If the alarm occurs again, save the CMOS.BIN in mainte- nance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||
4980 | DESTINATION PULSE LIMIT | Setting error | (1) Check the following settings. ∙Check the position setting for the step (move instruction) where the alarm occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4981 | DEST PULSE ME- CHANICAL LIMIT | Setting error | (1) Check the following settings. ∙Check the position setting for the step (move instruction) where the alarm occurred. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4982 | DEST MECHANI- CAL INTRF | Setting error | (1) Check the following settings. ∙Check the position setting for the step (move instruction) where the alarm occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4983 | DEST MECHANI- CAL INTRF | Setting error | (1) Check the following settings. ∙Check the position setting for the step (move instruction) where the alarm occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4984 | DESTINATION SELF-INTERFER- ENCE | Setting error | (1) Check the following settings. ∙Check the position setting for the step (move instruction) where the alarm occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4985 | TEACH LINE CORD JOG MOVE DIS- ABLE | Setting error | Correct the attitude of the tool and the ground are out of verti- cal, and execute teach line cord jog move. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4986 | TEACH LINE CORD JOG MOVC DIS- ABLE | Setting error | Execute FWD/BWD/TEST RUN operation, and execute teach line cord jog move. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4987 | WELD LINE CORD SHIFT MOV DIS- ABLE | 1 | IMPOSSIBLE MO- TION(Y direction) | Setting error | (1) Check the following settings. ∙Correct the teaching positions so that the attitude of the tool and the ground are out of vertical. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | IMPOSSIBLE MO- TION(Y direction) | Setting error | (1) Check the following settings. ∙The robot can not move to the target shift position. Change shift volume or modify the teaching position. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4988 | WELD LINE CO- ORD SHIFT DIS- ABLE | 1 | PREFLOW not exe- cuted | Setting error | (1) When executing weld line coordinate shift operation, start the JOB with one step before ARCON instruction. (2) When teaching the JOB for weld line coordinate shift oper- ation, set the ARCON instruction in the JOB in which the weld line coordinate shift operation is to be performed. (Don’t set ARCON instruction in the JOB which is target for CALL instruc- tion without setting any weld start teaching point.) To use ARCON instruction without weld start point in the CALL destination JOB, disable the weld line coordinated shift func- tion in the weld start condition file. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4989 | DEFECTIVE OPER- ATION VELOCITY | Sub Code: Control group | Setting error | (1) Check the following settings. ∙Please do not take effect safety of the speed limit by the func- tional safety during the interval of ARCON. | ||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4990 | MOTION ERROR (SINGULAR POS- TURE) | Sub Code: Control group | Setting error | (1) Check the following settings. ∙Change the teaching orientation. [Tube built-in wrist type models] When a flange is parallel to a XY plane of the robot coordinat- ed system, teach the flange so that it is inclined more than 0.01 degrees. | ||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your YASKAWA representative about occurrence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4991 | IO MODULE PROC OVERTIME | 16 | The procedure of the accessing to I/O mod- ule which is connect- ed with 1st PCI connector did not fin- ish in the defined peri- od. | Setting error | (1)Check the following settings. ∙When SST-DN4 is used; maximum waiting time for accessible to PCI board ∙PCI slot number in which each PCI board is mounted ∙I/O module settings in maintenance mode | |||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following connector. ∙The PCI connector of the corresponding I/O module | |||||||||||||||||||||||||||||||||||||
Board failure (I/O module) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙The corresponding I/O module (PCI board) | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
YIF board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
17 | The procedure of the accessing to I/O mod- ule which is connect- ed with 2nd PCI connector did not fin- ish in the defined peri- od. | Setting error | (1) Check the following settings. ∙When SST-DN4 is used; maximum waiting time for accessible to PCI board ∙PCI slot number in which each PCI board is mounted ∙I/O module settings in maintenance mode | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following connector. ∙The PCI connector of the corresponding I/O module | |||||||||||||||||||||||||||||||||||||
Board failure (I/O module) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙The corresponding I/O module (PCI board) | |||||||||||||||||||||||||||||||||||||
YIF board failure | (1)Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
18 | The procedure of the accessing to I/O mod- ule which is connect- ed with 3rd PCI connector did not fin- ish in the defined peri- od. | Setting error | (1) Check the following settings. ∙When SST-DN4 is used; maximum waiting time for accessible to PCI board ∙PCI slot number in which each PCI board is mounted ∙I/O module settings in maintenance mode | |||||||||||||||||||||||||||||||||||
Connection failure | (1)Turn the power OFF then back ON. (2)If the alarm occurs again, check the connection and inser- tion of the following connector. ∙The PCI connector of the corresponding I/O module | |||||||||||||||||||||||||||||||||||||
Board failure (I/O module) | (1)Turn the power OFF then back ON. (2)If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙The corresponding I/O module(PCI board) | |||||||||||||||||||||||||||||||||||||
YIF board failure | (1)Turn the power OFF then back ON. (2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. | |||||||||||||||||||||||||||||||||||||
19 | The procedure of the accessing to I/O mod- ule which is connect- ed with 4th PCI connector did not fin- ish in the defined peri- od. | Setting error | (1)Check the following settings. ∙When SST-DN4 is used; maximum waiting time for accessible to PCI board ∙PCI slot number in which each PCI board is mounted ∙I/O module settings in maintenance mode | |||||||||||||||||||||||||||||||||||
Connection failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, check the connection and inser- tion of the following connector. ∙The PCI connector of the corresponding I/O module | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
Board failure(I/O module) | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe. ∙The corresponding I/O module (PCI board) | |||||||||||||||||||||||||||||||||||||
YIF board failure | (1) Turn the power OFF then back ON. (2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred. |