Yaskawa Alarm Codes 4600 – 4699

Yaskawa Alarm Codes 4600 – 4699

Home > Yaskawa > Alarm Codes > Alarm Codes 4600 – 4699

Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4601UNDEFINED GUN COND FILE SUB-Code: Gun con- dition file numberSetting error(1) Check the following settings.
∙Complete the gun condition file setting.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4603WIRE STICKING SUB-Code: Welder numberSetting error(1) Check the following settings.
∙Remove the cause of wire stick.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4604SPECIFIED ERR (ABSO RECOVER AXIS)  Setting error(1) Check the following settings.
∙Registration for the home position correction data.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4605SETTOOL ERROR1The difference be- tween the current tool constant and a new set value exceeded the allowable range (parameter set val- ue).Setting error(1) Check the following settings.
∙Correct the JOB so that the setting value of tag is allowable val- ue.
∙Set the allowance amount of the tool data automatic setting func- tion maximum deviation (S3C1192) to large value.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4606LACK OF GLOBAL VARIABLE AREA  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4607WRONG EXECU- TION OF MACRO INST1The execution macro JOB is not set.Setting error(1) Check the following settings.
∙Check the settings for execution macro JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2The suspend macro JOB is not set.Setting error(1) Check the following settings.
∙Check the settings for suspend macro JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3An attempt was made to start the JOB that could not be started by the macro instruc- tion.Setting error(1) Check the following settings.
∙Check the settings for macro JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5An error occurred in the operation process of JOB call stack when the execution of macro instruction was cancelled.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  6Incorrect macro num- berSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4608WRONG EXECU- TION OF GETARG INST1The JOB argument is not set.Setting error(1) Check the following settings.
∙Check the settings for JOBs.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2No number of the specified JOB argu- mentSetting error(1) Check the following settings.
∙Check the settings for JOBs.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3The data types of JOB argument dis- agreed.Setting error(1) Check the following settings.
∙Check the settings for JOBs.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4609MEMOPLAY ER- ROR2The memory play file was being used in an- other system.Setting error(1) Check the following settings.
∙Check the setting of the used memory play file number.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5The control group in the memory play file did not agree with the control group of exe- cution JOB.Setting error(1) Check the following settings.
∙Check the control group setting of the used memory play file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6An attempt was made to clear the memory play file by a CLEAR instruction before having executed a MEMOF instruction.Setting error(1) Check the following settings.
∙Execute the MEMOF instruction, and then execute the CLEAR instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4610MEMOPLAY SAM- PLING ERROR1Failed to read the memory play sam- pling data.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2Failed to write the memory play sam- pling data.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3Failed to seek the memory play sam- pling data.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4Failed to read the memory play file.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5Incorrect mode set- ting at memory play samplingSetting error(1) Check the following settings.
∙Check the settings for the memory play mode.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Incorrect designation of the control group at memory play sam- plingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  7Designation of the control group in the memory play file did not agree with the designation of the control
group at MEMON in- struction execution (when the start point was specified).
Setting error(1) Check the following settings.
∙Check the number of the memory play file for use.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Designation of the control group in the memory play file did not agree with the designation of the control group at MEMON instruction execution (at initial- ization).Setting error(1) Check the following settings.
∙Check the number of the memory play file for use.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  9designation of the control group in the memory play file did not agree with the designation of the control
group at MEMON in- struction execution (at continue).
Setting error(1) Check the following settings.
∙Check the number of the memory play file for use.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  10It started reproducing though it did not re- cord.Setting error(1) Check the following settings.
∙Record and then play.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  11Correction amount to record is out of the al- lowable range.Setting error(1) Check the following settings.
∙Correct the position of object workpieces so that the correction amount fall within allowable range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  12The number of re- corded correction- amount exceeded the limit.Setting error(1) Check the following settings.
∙Correct the JOB so that the movement section of memory play object is shorter.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  13Memoplay file Create error (REC)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  14Memoplay debug er- ror C_BANK.func_c- trl (initial)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  15Memoplay debug er- ror C_BANK.func_c- trl (continue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  16Memoplay debug er- ror C_BANK RT_BANK.func_ctrl (continue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  17Memoplay debug er- ror MOVL, MOVC
(continue)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  18Memoplay debug er- ror Same point, mov- ing amount is zero (continue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  19Memoplay debug er- ror Dividing number errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4611OVER OPTON INST EXECUTION LIMIT  Setting error(1) Check the following settings.
∙Check the settings for the OPTON instruction. OPTON instruc- tion can use only the function to five simultaneously.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4612TSYNC ERROR SUB-Code: the num- ber of synchroniza- tions of the first executed TSYNCSetting error(1) Check the following settings.
∙Check the settings for the number of synchronizations of the TSYNC instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4613SERVO SEALER GUN CONTROL ERROR1The function designa- tion parameter is not set.Setting error(1) Check the following settings.
∙Check the settings for the function designation parameter.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2No sealer gun axis exists at the JOB for which the sealer gun control was attempt- ed to be executed.Setting error(1) Check the following settings.
∙Check the settings for the control-group of the JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3No robot axis exists at the JOB at which an attempt was made to execute sealer gun control.Setting error(1) Check the following settings.
∙Check the settings for the control-group of the JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Incorrect designation of the control method for sealer gun controlSetting error(1) Check the following settings.
∙Set either “1” or “2” for PRM1 control method designation of the OPTON instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Incorrect designation of the control method for sealer gun controlSetting error(1) Check the following settings.
∙If “1” is set for PRM1 of the OPTON instruction, set the PRM2 needle position designation to a value between 0 and 100.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Incorrect designation of the sealing width for sealer gun controlSetting error(1) Check the following settings.
∙If “2” is set for PRM1 of the OPTON instruction, set PRM2 sealing width designation to a value between 0 and 30.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4614UNDEFINED SEALERGUN COND FILE  Setting error(1) Check the following settings.
∙Check the settings for SERVO sealer gun condition file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4615I/O AXIS OPERAT- ING An attempt was made to command a JOB whose control group was in I/O axis mo- tion.Setting error(1) Check the following settings.
∙Does not the I/O axis motion executed for the control group that executing the JOB?
∙Does not the JOB executed for the control group that operating by the I/O axis motion?
The control group where the I/O axis is operating cannot execute the JOB. Moreover, the I/O axis motion cannot perform for the control group where the JOB is executing.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4616AXIS SHIFT ER- ROR1The file could not be switched because of incorrect start point designation.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2The control group with which the axis shifting is performed disagrees with the control group set for the axis shifting func- tion in the calibration file.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3The calibration file number for axis shift- ing function is out of the applicable range.Setting error(1) Check the following settings.
∙Correct the settings for the OPTON instruction tag so that value of the file number specification is 1 to 32.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4617S/U IMPOSSIBLE MOVE (L/R POS)1For the CSL15D ro- bot, the motion speed of S- and U-axes ex- ceeded the upper lim- it.Setting error(1) Check the following settings.
∙Reduce the teaching speed of S- and U-axes.
∙Teach the positions of L- and R-axes again so that S- and U-axes can move.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2For the CSL15D ro- bot, S- and U-axes were going to move regardless of the limit speed “0” when the positions of L- and R- axes exceeded the upper limit.Setting error(1) Check the following settings.
∙Teach the positions of L- and R-axes again so that S- and U-axes can move.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4618SHIFT INST EXE- CUTE ERROR1For the tool shift with Euler angle ± 90 de- grees, the shift value for axes other than Y- axis is set.Setting error(1) Check the following settings.
∙Check if the shift value is setting for Y-axis only.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4619UNDEFINED JOB ENTRY TABLE SUB-Code: Designat- ed registration num- berSetting error(1) Check the following settings.
∙Check the settings for the JOB registration table.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4620ARM (TOOL) IN- TERFERENCE SUB-Code: Group (Interferening) &Axis (Interfering) &Group (Interfered) &Axis (In- terfered)Setting error(1) Check the following settings.
∙Change the teaching so that the robots specified by SUB-Code will not interfere with each other.
∙Check if the tool model (Tool interference file) of the robot spec- ified by SUB-Code is correctly set.
∙Check if calibration between the robots are correctly set.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4621WELD COMPLETE SIGNAL ERROR SUB-Code: Welder numberSetting error(1) Check the following settings.
∙Check the settings for welding completion signal.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4622SELF-INTERFER- ENCE SUB-Code: Group&Axis(Interfer- ing)&Axis(Interfered)Setting error(1) Check the following settings.
∙Change the teaching so that each part of the robot specified by SUB-Code will not interfere.
∙Check if the tool model (Tool interference file) displayed by SUB- Code is correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4623WRONG EXECU- TION OF GETPOS INST1An attempt was made to obtain the step that used a local position type variable.
(The step with local position type variable cannot be fetched.
Example: MOVJ LP000 VJ=25.00)
Setting error(1) Check the following settings.
∙Check the settings for the GETPOS instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2An attempt was made to obtain the step that used a local position type variable.
(The step with local position type variable cannot be fetched.
Example: MOVJ LP000 VJ=25.00)
Setting error(1) Check the following settings.
∙Check the settings for the GETPOS instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3The specified step did not exist.Setting error(1) Check the following settings.
∙Check the settings for the GETPOS instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4624PLUG VOLUME SETTING ERROR  Setting error(1) Check the following settings.
∙Check the setting for the amount of fillings.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4625WRONG EXECU- TION OF LOADDB INST1No fileSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2No directorySoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4There was no directo- ry entry after this point.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -1No file nameSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -2File presence errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -3Incorrect file nameSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -4The disk is full.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -5The directory is full.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -6I/O errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -7Invalid handleSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -8Handle overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -9File has already been opened.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -10File attribute errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -11Open mode errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -12The hardware disk with large capacity is used.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -14The door is open.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -15The disk is write-pro- tected.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -30Card controller ac- cess errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -31No cardSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -32Card drive informa- tion readout errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -33Partition table errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -34No drive numberSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -35No specified partition numberSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -36Cluster size errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -37Incorrect number of sectorsSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -38Sector/byte errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -40Card not applicable for I/OSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -41Unsupported versionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -42The setting register did not exist.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -43Card not applicable for ATASoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -44Double chain errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -45Media error (not fixed disk)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -50ATA command in- completeSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -51Sector read com- mand errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -52Sector write com- mand errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4626IMPOSSIBLE S- AXIS MOV (IN SPHERE)  Setting error(1) Check the following settings.
∙Check the settings for the limit distance for S-axis rotation center motion (S1CG067).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4627GUN RECOGNI- TION SIGNAL OFF SUB-Code: Gun numberSetting error(1) Check the following settings.
∙Check the settings for the gun identification signal.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4628WRITE VARIABLE NO. MULTI SET- TING SUB-Code: Duplicat- ed variable numberSetting error(1) Check the following settings.
∙Check the settings for the written destination variable numbers.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4629GROUP CHANGE ERROR1The group change pa- rameter was invalid.Setting error(1) Check the following settings.
∙Validate the group change parameter.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2The GRPCHG in- struction was execut- ed while the external axis motor was SER- VO ON.Setting error(1) Check the following settings.
∙Execute the GRPCHG instruction when the external axis motor was SERVO OFF.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3The GRPCHG in- struction was execut- ed in unchuck status.Setting error(1) Check the following settings.
∙Execute the GRPCHG instruction in chuck status.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4The group identifica- tion signal was not re- ceived.Setting error(1) Check the following settings.
∙Check the settings for group identification signal.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5The specified control group number and the group identification number were un- matched.Setting error(1) Check the following settings.
∙Check the settings for the specified control group number.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6The encoder PG pow- er supply was OFF when the GRPCHG was ON.Setting error(1) Check the following settings.
∙Turn ON the encoder PG power supply when GRPCHG is ON.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7The encoder PG pow- er supply was ON when the GRPCHG was OFF.Setting error(1) Check the following settings.
∙Turn OFF the encoder PG power supply when GRPCHG is OFF.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8The control group that corresponded to the received group identi- fication signal did not exist.Setting error(1) Check the following settings.
∙Check the settings for group identification signal.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4630DUPLICATED GUN NUMBER SUB-Code: The over- lapped gun numberSetting error(1) Check the following settings.
∙Check the settings for gun numbers.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4631DEFECTIVE OPER- ATION VELOCITY SUB-Code: Control group and axisSetting error(1) Check the following settings.
∙Check if the speed is hold down by the speed override and spe- cial operations etc.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4632UNDEFINED LNR SCALE FILE SUB-Code: Linear scale characteristic file numberSetting error(1) Check the following settings.
∙Complete the settings for the linear scale condition file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4633FOLLOWING ER- ROR1An error occurred when executing a FOLLOW instruction. An attempt was made to re-execute the FOLLOW instruction after interrupting it.Setting error(1) Check the following settings.
∙Re-execute the move instruction executed before the FOLLOW instruction, and then execute the FOLLOW instruction again.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4634FOLLOWING SPEED OVER  Setting error(1) Check the following settings.
∙Reduce the bending speed.
∙Reduce the robot moving distance.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4635CANNOT EXE- CUTE COMMON JOB SUB-Code: The relat- ed control-groupSetting error(1) Check the following settings.
∙Check the settings for control group specified by the CALL in- struction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4636THICKNESS ER- ROR SUB-Code: Gun numberSetting error(1) Check the following settings.
∙Weld the spot by thickness within allowable range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4637TRACK CHG WORK IN/NOT NOT FOUND SUB-Code: Conveyor characteristic file numberSetting error(1) Check the following settings.
∙Check the workpiece presence/absence and data settings for the synchronization section.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4638TRACKING CHG WORK ID NOT FOUND SUB-Code: Conveyor characteristic file numberSetting error(1) Check the following settings.
∙Check the workpiece presence/absence and data settings for the synchronization section.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4639SYMOVJ INST EX- ECUTE ERROR2The conveyor moving amount is not speci- fied for the SYMOVJ motion.Setting error(1) Check the following settings.
∙Set the conveyor moving amount for the SYMOVJ motion.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3An error occurred in the preparation pro- cess of the robot mo- tion start position for the SYMOVJ motion.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4An error occurred in the preparation pro- cess of the robot mo- tion end position for the SYMOVJ motion.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4640WRONG EXECU- TION OF PSTART INST1No axis data of con- trol group to be dis- connectedSetting error(1) Check the following settings.
∙Check the settings for PSTART instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2An attempt was made to disconnect a con- trol group other than the occupation con- trol group during pre- reading processing.Setting error(1) Check the following settings.
∙Check the settings for PSTART instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3An attempt was made to disconnect a con- trol group other than the occupation con- trol group when exe- cuting a PSTART instruction.Setting error(1) Check the following settings.
∙Check the settings for PSTART instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4641CANNOT EXE- CUTE JOB (SEPARATE GRP) SUB-Code: The dis- connected control group used by a move instructionSetting error(1) Check the following settings.
∙Correct the teaching so that the control group disconnected by it- self is not to operate for move instruction of own system.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4644SPOT WELDER I/F ERROR (ASW)8The controller could not send an instruc- tion to the welder be- cause the welder was busy in processing.Connection failure(1) Reset the alarm.
(2) If the alarm occurs again, check the connection and inserting state of the following cables and connectors.
∙DENGENSHA welding I/F board
∙NADEX DeviceNet cable
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  9Welding current error at welding is complet- ed successfully.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  10Abnormal code error at welding is complet- ed successfully.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  11Welding command process exceptional errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  102The specified welder number (system) could not be found.Setting error(1)Check the following setting.
∙Confirm the specified welder number (system) and the setting.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4645NOT PERMIT FIXED-WEAV ON SWVON  Setting error(1)Check the following setting.
∙Check the settings for JOBs.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4648FILE TRANSFER ERROR (ARITH)1Motion range file transfer errorSetting error(1)Check the following setting.
∙Check if the motion range file is correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Part motion range file transfer errorSetting error(1)Check the following setting.
∙Check if the part motion range is correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4649PARTIAL MOTION RANGE INTRF. SUB-Code: Interfer- ence control group number & interfer- ence axis & interfer- ence area number.Setting error(1)Check the following setting.
∙Check the setting of the teaching position of the robot.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4650TRQ CLEAR ER- ROR  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4651PALLETIZING EXE- CUTE ERROR1The setting of the pal- letizing condition con- figuration file is incomplete.Setting error(1) Check the following settings.
∙Set the palletizing condition setting file to “Completed”.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Palletize completion universal output num- ber range exceeds the limit.Setting error(1) Check the following settings.
∙Change the palletize completion universal output signal number of the palletizing condition setting file in the user output signal point of contact number.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5During the palletize start instruction exe- cution, the palletize start instruction is ex- ecuted again (double execution).Setting error(1) Check the following settings.
∙Delete the palletize start instruction in the palletize section.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6The value of the pal- letizing number pres- ent value output register (or I variable) is more than the total number output regis- ter (or I variable).Setting error(1) Check the following settings.
∙Check if the palletizing number of current position output register (or I variable) and total number of output register (or I variable) is not changed by another function.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Palletize completion universal output sig- nal is turned ON at palletize start instruc- tion execution.Setting error(1) Check the following settings.
∙Reset the palletize completion universal output signal.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Palletize end instruc- tion is not registered.Setting error(1) Check the following settings.
∙Register the palletizing end instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4652TRQ MEASURE MODE SET ERR (SV)  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4653TRQ MEASURE MODE CANCEL ERR (SV)  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4654WRONG EXECU- TION OF SETREG INST1An attempt was made to change the value of the analog input reg- ister.Setting error(1) Check the following settings.
∙The SETREGM instruction cannot change the analog input reg- ister values. Correct the setting of tag that specifies register num- ber of SETREG instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2An attempt was made to change the value of the register currently used by TMR/CNT.Setting error(1) Check the following settings.
∙The SETREGM instruction cannot change the register values used in TMR/CNT. Correct the setting of tag that specifies register number of SETREG instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  65535An attempt was made to change the value of the register currently used by TMR/CNT.Setting error(1) Check the following settings.
∙Correct the setting of tag that specifies register number of SE- TREG instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4655WRONG EXECU- TION OF GETREG INST65535An attempt was made to acquire the value of the register not exist- ing.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4656WRONG EXECU- TION OF SETPRM INST1An attempt was made to change a parame- ter other than the cube-related parame- ter.Setting error(1) Check the following settings.
∙The SETPRM instruction cannot change the parameter values other than the parameter related to the cube. Correct the setting of tag that specifies parameter number of SETPRM instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2The SETPRM instruc- tion was executed while another system was in execution.Setting error(1) Check the following settings.
∙The SETPRM instruction cannot execute while another system is operating. Correct the JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4657WVADJ ERROR1The correction ampli- tude value did not fall in the limit range.Setting error(1) Check the following settings.
∙Correct the settings for “groove width correction limit value” spec- ified for S2C1259 and 1260.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4658OVER SPEED LIM- IT1The taught speed was going to exceed the limit during the multi arm simultaneous op- eration.Setting error(1) Check the following settings.
∙Reduce the teaching speed of the step where the alarm occurred to the speed limit or less.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4659TIP DRESS WATCH SET ERROR  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4660TIP DRESS WATCH CANCEL ERROR  Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4661MEMORY ERROR (PRESS COND FILE) SUB-Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the press characteristic file in MAINTENANCE mode, and then load the press characteristic file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4662PRESS SYNCHRO- NOUS ERROR5Unable to set the cor- rection data for the press synchronous control.Setting errorThe alarm occurs if the MOVE instruction except MOVJ with ENC tag is operated during Press synchronous control.
Reset the press synchronous control by the following operations to operate the MOVE instruction expect MOVJ with ENC tag.
∙Confirm that press machine and robot must be stopped
∙Make Specific Input PRESS SYNC OFF(#41010) ON
∙Confirm that the Specific Output PRESS SYNC (#50683) is OFF.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4666UNDEFINED WELD LENGTH CHECK FILE  Setting error(1) Check the following settings.
∙Complete the settings for the weld length check condition file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4667DEFECTIVE GUN PRESSURE FILE SUB-Code: Gun pressure file numberSetting error(1) Check the following settings.
∙Match the number of “END WAIT” in the gun pressure file, and the number of “Welding Conditions(WTM)” in the instruction.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4668MEMORY ERROR (PREVENTION FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the MAINTENANCE pre- vention file in MAINTENANCE mode, and then load the MAINTE- NANCE prevention file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4669DETECT BRAKE SLIP SUB-Code: Signifies the axis in which the alarm occurredModule failure (mo- tor)(1) Reset the alarm.
(2) If the alarm occurs again, replace the motor.
(3)If the alarm of „external brake“ is occurred, replace the external brake.
    Setting error(1)Reset the alarm.
(2)Check the following settings.
·Check torque value.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4670INSUFFICIENT NUM OF SAMPLE DATA SUB-Code: Signifies the axis in which the alarm occurredSetting error(1) Reset the alarm.
(2)Lengthen the measurement section.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4671SAMPLE BUFFER OVER FLOW SUB-Code: Signifies the axis in which the alarm occurredSetting error(1) Reset the alarm.
(2)Shorten the measurement section.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4672BASIC SPEED UN- REACHED SUB-Code: Signifies the axis in which the alarm occurredSetting error(1) Reset the alarm.
(2)Increase the speed specification value of a measurement JOB or set a small value for BASICV.
Or set a small value for BASICT, or lengthen the measurement section.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4673MAX TRQ UNDE- TECTED SUB-Code: Signifies the axis in which the alarm occurredSetting error(1) Reset the alarm.
(2)Set a large value for the BASICT, and then check again.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4674SETE ERROR1An attempt was made to set tool for base/ station-axis position- type variable.Setting error(1) Check the following settings.
∙Check the settings for JOBs.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4676BROKEN FAN FUSE1SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8SUB-Code 1to 8: Sig- nifies the EAXA/ EAXB board No. in which the alarm oc- curredConnection failure(1) Reset the alarm.
(2) If the alarm occurs again, check if there is a ground fault or short circuit in the fan power line.
    Fuse failure(After cancellation of the short-circuit and ground fault) Replace the fuse.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4677IMPOSSIBLE LIN- EAR MOTION SUB-Code: Control group and axisSetting error(1) Check the following settings.
∙If the SUB-Code display is L- and U-axes, perform the teaching again to make the form (arm folded direction) of L- and U-axes same at start point and end point.
∙If the SUB-Code display is S- and L-axes, perform the teaching again to make the form (arm folded direction) of S- and L-axes same at start point and end point.
∙Change the teaching move instruction to MOVJ instruction.
* Be careful to the peripheral interference since its movement changes.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4678SPOT MONITOR DATA ERROR SUB-Code: Internal control error in soft- wareSoftware operation error occurred(1) Reset the alarm.
(2) If the alarm occurs again, initialize the database of spot weld history.
(3) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4680F-SAFE COM- MAND ERROR (YCP21) The previous com- mand was not com- pleted.
SUB-Code: Function- al safety board station number.
Software operation error occurredReset the alarm, and then try again.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4681OVER SPEED
(MainCPU)
 SUB-Code: Control group and axisSetting error(1) Check the following settings.
∙Reduce the speed of the step where the alarm occurred.
∙Change the move instruction to joint interpolation (MOVJ).
* Be careful to the peripheral interference since its movement changes.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4684INTERPOLATION INVALID SUB-Code: Control groupSetting error(1) Check the following settings.
∙At the Cartesian jog operation, switch to each-axes jog opera- tions, and then change the orientation of robot.
∙Change the teaching position and orientation.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4685F-SAFE WRITE ER- ROR0An error occurred in the parameter write operation.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  1An error occurred in the file write opera- tion.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Write request has timed out.Software operation error occurred(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4692F-SAFE ENCODER BACKUP ERROR  Encoder battery fail- ure(1) Reset the alarm.
(2)If AL4311 occurred simultaneously with this alarm, execute the trouble shooting for the AL4311.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4693F-SAFE READ- BACK PROC. ER- ROR0Readback value of CPU1 and CPU2 mis- match.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  1Another readback re- quest was issued to the readback pro- cess. (Parameter)Software operation error occurred(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Another readback re- quest was issued to the readback pro- cess. (File)Software operation error occurred(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Incorrect file type.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Incorrect file number.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Incorrect write data.Data error(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Process order error.Software operation error occurred(1) Reset the alarm.
(2)Try the write operation again.
    YSF25 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YSF25 board. Save the CMOS.BIN before replace the board to be safe.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4696TURN TABLE CALI- BRATION ERROR1There was the same point in three points where the calibration had been executed.Setting error(1) Check the following settings.
∙Correct the calibration position so that each point is different.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2The three points where the calibration had been executed lie in a straight line.Setting error(1) Check the following settings.
∙Check the calibration position so that the three taught points are not aligned in a straight line.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3The three points where the calibration had been executed lie in a straight line.Setting error(1) Check the following settings.
∙Check the calibration position so that the three taught points are not aligned in a straight line.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4697OFFLINE ARM BEND POS CON- VERT ERR1Incorrect information of standard position data for offline arm bend position data conversionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Incorrect user-coordi- nate number in the standard position data for offline arm bend position data conversionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3Incorrect reference- point data offline arm bend position data conversionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4The position data could not be convert- ed correctly/con- versely for the standard position data at the offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Incorrect pulse incre- mental value for of- fline arm bend position data conver- sionSetting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6The position data could not be convert- ed correctly for the pulse incremental val- ue at the offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Incorrect Cartesian incremental value for offline arm bend posi- tion data conversionSetting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8The position data could not be convert- ed correctly for the Cartesian incremen- tal value at the offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  9The position conver- sion could not be done in the conver- sion data for offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  10Incorrect incremental value of angle for of- fline arm bend posi- tion data conversionSetting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  11The position data could not be convert- ed correctly for the in- cremental value of angle at the offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  12The gravity moment for offline arm bend position data conver- sion could not be cal- culated.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  13The position data could not be convert- ed correctly for the re- vised conversion data at the offline arm bend position data conversion.Setting error(1) Check the following settings.
∙The variable position may be out of the robot motion range. Check if the variable position is within the robot motion range.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4698SHIFT VALUE MAKING ERROR1Reference position and target position occupation control- group errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2Reference position and target position enabling control- group errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3The position data type is not applicable.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4Coordinated control- group errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5User coordinates number on the speci- fied tag side errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4699SYSTEM ERROR 1 (RSC1) SUB-Code
Internal control error in software
Software operation error occurred(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).