Yaskawa Alarm Codes 4250 – 4299

Yaskawa Alarm Codes 4250 – 4299

Home > Yaskawa > Alarm Codes > Alarm Codes 4250 – 4299

4250MOTOWELD DIGI- TAL I/F ERROR1Error from welder 1.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7Error from welder 7.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  403SUB-Code: Error No. from welder.Arc welding power source errorConfirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4251MOTOWELD DIGI- TAL I/F FILE# ER- ROR1Error from welder 1.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorSet the user file number 1…16.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorSet the user file number 1…16.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  404SUB-Code: Error No. from welder.Arc welding power source errorSet the user file number 1…16.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4252MOTOWELD DIGI- TAL I/F CHIP ER- ROR1Error from welder 1.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
  405SUB-Code: Error No. from welder.Arc welding power source errorReplace the main board {Pr(MB) -024}. Contact your YASKAWA representative.
4253MOTOWELD MA- CHINE TYP.ER- ROR11Error from welder 1.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  304SUB-Code: Error No. from welder.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
4254MOTOWELD MA- CHINE TYP.ER- ROR21Error from welder 1.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  305SUB-Code: Error No. from welder.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
4255MOTOWELD MA- CHINE TYP.ER- ROR31Error from welder 1.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  306SUB-Code: Error No. from welder.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
4256MOTOWELD MA- CHINE TYP.ER- ROR41Error from welder 1.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
  307SUB-Code: Error No. from welder.Arc welding power source errorThe setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative.
4257MOTOWELD PAN- EL SW SETTING ERROR1Error from welder 1.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  2Error from welder 2.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  3Error from welder 3.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  4Error from welder 4.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  5Error from welder 5.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  6Error from welder 6.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  7Error from welder 7.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
  303SUB-Code: Error No. from welder.Arc welding power source error(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative.
4258MOTOWELD FEEDER ERROR1Error from welder 1.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Error from welder 3.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7Error from welder 7.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  501SUB-Code: Error No. from welder.Arc welding power source errorConfirm the following content.
(1)The encoder cable be not damaged?
(2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block?
When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  331The status of dip switch for encoder cir- cuit is different to the encoder of the feeder motor.Arc welding power source error(1)Confirm the feeder motor type.
(2)Check the C parameter for feeder motor is correct.
(3)Check the dip switch SW700 on the Main board Pr(MB).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4259MOTOWELD MO- TOR OVER-CUR- RENT1Error from welder 1.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and coduit cable are  not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Error from welder 3.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  502SUB-Code: Error No. from welder.Arc welding power source errorCheck if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4260MOTOWELD CPU ERROR11Error from welder 1.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  2Error from welder 2.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  3Error from welder 3.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  4Error from welder 4.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  5Error from welder 5.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  6Error from welder 6.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  7Error from welder 7.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  8Error from welder 8.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  203SUB-Code: Error No. from welder.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
4261MOTOWELD CPU ERROR21Error from welder 1.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  2Error from welder 2.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  3Error from welder 3.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  5Error from welder 5.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  6Error from welder 6.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  7Error from welder 7.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  8Error from welder 8.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  204SUB-Code: Error No. from welder.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
4262MOTOWELD MEM- ORY ERROR11Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  205SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4263MOTOWELD MEM- ORY ERROR21Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  215SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4264MOTOWELD MEM- ORY ERROR31Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  206SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4265MOTOWELD MEM- ORY ERROR41Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  207SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4266MOTOWELD MEM- ORY ERROR51Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  208SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4267MOTOWELD MEM- ORY ERROR61Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  209SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4268MOTOWELD MEM- ORY ERROR71Error from welder 1.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
  210SUB-Code: Error No. from welder.Arc welding power source errorThe data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”)
If the error occurs again, the board may be broken. Contact your YASKAWA representative.
4269MOTOWELD STARTING SIGNAL ERROR1Error from welder 1.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  601SUB-Code: Error No. from welder.Arc welding power source errorCheck again the operation timing or signal cable connections. The same error may occur at momentary power failure.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4270MOTOWELD NO WELDING TYPE1Error from welder 1.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorSelect a correct welding process in the using the welding user file.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  602SUB-Code: Error No. from welder.Arc welding power source errorSelect a correct welding process in the using the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4271MOTOWELD VOLT.DETECT WIRE ERROR1Error from welder 1.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  702SUB-Code: Error No. from welder.Arc welding power source error(1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD.
(2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4272MOTOWELD SAFTY-CIRCUIT ERROR1Error from welder 1.Arc welding power source errorContact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorContact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorContact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorContact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorContact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorContact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7Error from welder 7.Arc welding power source errorContact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorContact your YASKAWA representative.
  101SUB-Code: Error No. from welder.Arc welding power source errorContact your YASKAWA representative.
4273MOTOWELD IGBT SHORT CIRCUIT1Error from welder 1.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Error from welder 6.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  104SUB-Code: Error No. from welder.Arc welding power source errorReplace the IGBT device (Part code AJ0EL3870).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4274MOTOWELD VOLT- AGE DETECTOR ERROR1Error from welder 1.Arc welding power source errorContact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorContact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorContact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorContact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorContact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Error from welder 6.Arc welding power source errorContact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorContact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorContact your YASKAWA representative.
  110SUB-Code: Error No. from welder.Arc welding power source errorContact your YASKAWA representative.
4275MOTOWELD AUX. CIRCUIT OV. CUR- RENT1Error from welder 1.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  2Error from welder 2.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  3Error from welder 3.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  4Error from welder 4.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  5Error from welder 5.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  6Error from welder 6.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  7Error from welder 7.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  8Error from welder 8.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
  111SUB-Code: Error No. from welder.Arc welding power source errorThe board may be broken. Contact your YASKAWA representa- tive.
4276MOTOWELD DSP ADC ERROR1Error from welder 1.Arc welding power source errorContact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source errorContact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorContact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorContact your YASKAWA representative.
  5Error from welder 5.Arc welding power source errorContact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorContact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorContact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorContact your YASKAWA representative.
  119SUB-Code: Error No. from welder.Arc welding power source errorContact your YASKAWA representative.
4277MOTOWELD OUT- SIDE OF CURR.SETTING(H)1Error from welder 1.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  790SUB-Code: Error No. from welder.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4278MOTOWELD OUT- SIDE OF CURR.SETTING(L)1Error from welder 1.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  791SUB-Code: Error No. from welder.Arc welding power source error(1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09.
(2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command.
(3) Check that the wire stick out is not excessively short or long.
(4) Check that the range set in C parameter C29 is not too narrow.
(5) Check if the wire, shielding, etc. are correctly set.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4279MOTOWELD MO- MENTARY
OVER-CURR
1Error from welder 1.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  2Error from welder 2.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  3Error from welder 3.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  5Error from welder 5.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  6Error from welder 6.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  7Error from welder 7.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  8Error from welder 8.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
  108SUB-Code: Error No. from welder.Arc welding power source error(1) Check that short-circuit or the earth grounded of the output ca- ble.
(2)May be power circuit broken. Contact your YASKAWA repre- sentative.
4280MOTOWELD OVER-VOLTAGE1Error from welder 1.Arc welding power source errorContact your YASKAWA representative.
  2Error from welder 2.Arc welding power source errorContact your YASKAWA representative.
  3Error from welder 3.Arc welding power source errorContact your YASKAWA representative.
  4Error from welder 4.Arc welding power source errorContact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorContact your YASKAWA representative.
  6Error from welder 6.Arc welding power source errorContact your YASKAWA representative.
  7Error from welder 7.Arc welding power source errorContact your YASKAWA representative.
  8Error from welder 8.Arc welding power source errorContact your YASKAWA representative.
  109SUB-Code: Error No. from welder.Arc welding power source errorContact your YASKAWA representative.
4281MOTOWELD +15V POWER SUPPLY ERROR1Error from welder 1.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  704SUB-Code: Error No. from welder.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4282MOTOWELD POW- ER SUPPLY ER- ROR1Error from welder 1.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  705SUB-Code: Error No. from welder.Arc welding power source errorReplace the switching power supply unit. (Service parts code:AJ0E35055)
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4283MOTOWELD ILLE- GAL WELD TYPE1Error from welder 1.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  406A wrong welding pro- cess is set in the welding user file.Arc welding power source errorConfirm the welding process setting in the welding user file.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  407A welding type is not set in a user file of the MOTOWELD.Arc welding power source errorSet a welding type to user file of MOTOWELD. The user file can setup in the editor screen for ARC START CONDITION FILE or ARC END CONDITION FILE of the DX200.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4284MOTOWELD SOFTWARE MUL- FUNCTION310The version of the data base is not suit- able for the software of the welding power source.Arc welding power source errorLoad the suitable database.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  311The version informa- tion of the PLD on the main board Pr(MB) is wrong.Arc welding power source errorReplace the main board {Pr(MB) -030}.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  312The version of the firmware of front pan- el is not suitable for the software of the main board Pr(MB).Arc welding power source errorReplace the front panel {Panel-CR30 unit}.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  316The check sum of the PLD on the main board Pr(MB) is wrong.Arc welding power source errorReplace the main board {Pr(MB) -030}.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  317The program or data base was load by the ethernet.Arc welding power source errorReboot the power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  318The check sum error of loading data.Arc welding power source error(1)Do not turn off the power source and reload the data.
(2)In case of turn off and reboot was OK, reload the data.
(3)In case of turn off and reboot was NG, load the data by special loading tool.
(4)Other case of step 1,2,3, replace the main board Pr(MB)-030.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  400Watch dog error of the PLD.Arc welding power source error(1) Reboot the power source.
(2) Replace the main board {Pr(MB) -030}.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4285MOTOWELD MA- CHINE SETTING ERROR320The machine type is wrong.Arc welding power source error(1) Check the connection between front panel and main board.
(2) Check the status of dip switch (SW301) on the front panel.
(3) Replace the front panel.
(4) Replace the main board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4286MOTOWELD CUR- RENT CLASS ER- ROR330The current class 350A / 500A setting is wrong.Arc welding power source error(1) Confirm the power source class which of 350A or 500A.
(2) Switch a status of dip switch SW600 which of 350A or 500A.
(3)Change the software which for correct current class.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4290TPS:ERROR1no Prg
SUB-Code[1**] shows the error code of Fronius power source
1:main error code
**:sub error code
Arc welding power source errorSelect a pre-programmed program. Confirm the Fronius’s manual.
  2ts1
SUB-Code[2**] shows the error code of Fronius power source
2:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  3ts2
SUB-Code[3**] shows the error code of Fronius power source
3:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  4ts3
SUB-Code[4**] shows the error code of Fronius power source
4:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5tp1
SUB-Code[5**] shows the error code of Fronius power source
5:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  6tp2
SUB-Code[6**] shows the error code of Fronius power source
6:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  7tp3
SUB-Code[7**] shows the error code of Fronius power source
7:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  8tp4
SUB-Code[8**] shows the error code of Fronius power source
8:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  9tp5
SUB-Code[9**] shows the error code of Fronius power source
9:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  10tp6
SUB-Code[10**] shows the error code of Fronius power source
10:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  11Errtf1
SUB-Code[11**] shows the error code of Fronius power source
11:main error code
**:sub error code
Arc welding power source errorChange the thermo-sensor on the sec. side. Confirm the Fronius’s manual.
  12Errtf2
SUB-Code[12**] shows the error code of Fronius power source
12:main error code
**:sub error code
Arc welding power source errorChange the thermo-sensor on the sec. side. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  13Errtf3
SUB-Code[13**] shows the error code of Fronius power source
13:main error code
**:sub error code
Arc welding power source errorCheck cable tree of temperature sensors. Confirm the Fronius’s manual.
  14Errtf4
SUB-Code[14**] shows the error code of Fronius power source
14:main error code
**:sub error code
Arc welding power source errorOnly for MagicWave power source. Confirm the Fronius’s manual.
  15Errtf5
SUB-Code[15**] shows the error code of Fronius power source
15:main error code
**:sub error code
Arc welding power source errorCheck cable tree of temperature sensors. Confirm the Fronius’s manual.
  16Errtf6
SUB-Code[16**] shows the error code of Fronius power source
16:main error code
**:sub error code
Arc welding power source errorChange BPS pc-board. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  17DSPE05
SUB-Code[17**] shows the error code of Fronius power source
17:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  18ErrbPS
SUB-Code[18**] shows the error code of Fronius power source
18:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board or otherwise change the BPS board.
Confirm the Fronius’s manual.
  19Err IP
SUB-Code[19**] shows the error code of Fronius power source
19:main error code
**:sub error code
Arc welding power source errorChange the BPS board. Change the secondary diode.
Change the welding transformer. Confirm the Fronius’s manual.
  20DSPAxx
SUB-Code[20**] shows the error code of Fronius power source
20:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  21DSPExx
SUB-Code[21**] shows the error code of Fronius power source
21:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  22ErrEPF
SUB-Code[22**] shows the error code of Fronius power source
22:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  23Err23.x
SUB-Code[23**] shows the error code of Fronius power source
23:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  24Err24.x
SUB-Code[24**] shows the error code of Fronius power source
24:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  25Err25.x
SUB-Code[25**] shows the error code of Fronius power source
25:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual
  26Err26.x
SUB-Code[26**] shows the error code of Fronius power source
26:main error code
**:sub error code
Arc welding power source errorCheck whether the CfgMem has good contact to the connecting cables and in the plug.
Re-crimp if necessary.
If this does not help, remove and send to Fronius Austria, together with details of the series number of the machine.
Confirm the Fronius’s manual
  27Err027
SUB-Code[27**] shows the error code of Fronius power source
27:main error code
**:sub error code
Arc welding power source errorMeasure the +24VDC of NT 24. Confirm the Fronius’s manual
  28Err028
SUB-Code[28**] shows the error code of Fronius power source
28:main error code
**:sub error code
Arc welding power source errorChange the cooling-unit temperature sensor. Confirm the Fronius’s manual
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  29DSPC
SUB-Code[29**] shows the error code of Fronius power source
29:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  30EFd
SUB-Code[30**] shows the error code of Fronius power source
30:main error code
**:sub error code
Arc welding power source errorCheck the wire-feed system. Confirm the Fronius’s manual.
  31Err31
SUB-Code[31**] shows the error code of Fronius power source
31:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  32EcF
SUB-Code[32**] shows the error code of Fronius power source
32:main error code
**:sub error code
Arc welding power source errorInstall correct primary BPS power module. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  33tSt
SUB-Code[33**] shows the error code of Fronius power source
33:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  34Errtf7
SUB-Code[34**] shows the error code of Fronius power source
34:main error code
**:sub error code
Arc welding power source errorChange the UST board. Confirm the Fronius’s manual.
  35DSP KL
SUB-Code[35**] shows the error code of Fronius power source
35:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  36DSPnSy
SUB-Code[36**] shows the error code of Fronius power source
36:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board Confirm the Fronius’s manual
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  37US POL
SUB-Code[37**] shows the error code of Fronius power source
37:main error code
**:sub error code
Arc welding power source errorChange over the polarity of the two cables otherwise change the UST board
Confirm the Fronius’s manual
  38-Stop-
SUB-Code[38**] shows the error code of Fronius power source
38:main error code
**:sub error code
Arc welding power source errorDeactivate the -Stop- by input -RobotReady- and activate briefly
-SourceErrorReset-.
Confirm the Fronius’s manual.
  39NoH2O
SUB-Code[39**] shows the error code of Fronius power source
39:main error code
**:sub error code
Arc welding power source errorCheck the coolant level and (if appropriate) the coolant return- flow rate
If necessary, clean the coolant filter. Rate-of-flow watchdog may be defective. Confirm the Fronius’s manual.
  49Err049
SUB-Code[49**] shows the error code of Fronius power source
49:main error code
**:sub error code
Arc welding power source errorCheck the mains power supply. Check all 3 phases.
Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  50Err050
SUB-Code[50**] shows the error code of Fronius power source
50:main error code
**:sub error code
Arc welding power source errorDisconnect NT60 or change/check NT24/UST/BPS/intermediate circuit capacitors.
Confirm the Fronius’s manual.
  51Err051
SUB-Code[51**] shows the error code of Fronius power source
51:main error code
**:sub error code
Arc welding power source errorMains voltage too low or NT 24 defective. Confirm the Fronius’s manual.
  52Err052
SUB-Code[52**] shows the error code of Fronius power source
52:main error code
**:sub error code
Arc welding power source errorMains voltage too high or NT 24 defective. Confirm the Fronius’s manual.
  53ErrPE
SUB-Code[53**] shows the error code of Fronius power source
53:main error code
**:sub error code
Arc welding power source errorLow-resistance connection between secondary and machine housing find out the cause.
Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  54Err054
SUB-Code[54**] shows the error code of Fronius power source
54:main error code
**:sub error code
Arc welding power source errorIncrease the bbc (burn-back control) Switch off “Wire stick” in the set-up menu
After the end of welding, make sure that the wire does not collide with the workpiece when the torch is retracted.
Confirm the Fronius’s manual.
  55NoIGn
SUB-Code[55**] shows the error code of Fronius power source
55:main error code
**:sub error code
Arc welding power source errorSet a lower Ito value
Keep the torch stand-off distance smaller before ignition. Confirm the Fronius’s manual.
  56Err056
SUB-Code[56**] shows the error code of Fronius power source
56:main error code
**:sub error code
Arc welding power source errorCheck how much wire is left on the spool If necessary, change the spool.
Confirm the Fronius’s manual.
  57NoGAS
SUB-Code[57**] shows the error code of Fronius power source
57:main error code
**:sub error code
Arc welding power source errorCheck what volume of gas is still available. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  58NoArc
SUB-Code[58**] shows the error code of Fronius power source
58:main error code
**:sub error code
Arc welding power source errorCheck the seam.
Confirm the Fronius’s manual.
  59Err059
SUB-Code[59**] shows the error code of Fronius power source
59:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
  60Err060
SUB-Code[60**] shows the error code of Fronius power source
60:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
  61ErrArc
SUB-Code[61**] shows the error code of Fronius power source
61:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  62Err062
SUB-Code[62**] shows the error code of Fronius power source
62:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  63EIF
SUB-Code[63**] shows the error code of Fronius power source
63:main error code
**:sub error code
Arc welding power source errorCheck the interface configuration. Confirm the Fronius’s manual.
  64Errtf8
SUB-Code[64**] shows the error code of Fronius power source
64:main error code
**:sub error code
Arc welding power source errorChange the thermo-sensor of the cooling unit. Confirm the Fronius’s manual.
  65hotH2O
SUB-Code[65**] shows the error code of Fronius power source
65:main error code
**:sub error code
Arc welding power source errorCool down the cooling liquid. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  66tJo
SUB-Code[66**] shows the error code of Fronius power source
66:main error code
**:sub error code
Arc welding power source errorAllow the JOBMaster torch to cool. Confirm the Fronius’s manual.
  67ErrtJo
SUB-Code[67**] shows the error code of Fronius power source
67:main error code
**:sub error code
Arc welding power source errorChange JOBMaster pc-board. Confirm the Fronius’s manual.
  68Err068
SUB-Code[68**] shows the error code of Fronius power source
68:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
  69Err069
SUB-Code[69**] shows the error code of Fronius power source
69:main error code
**:sub error code
Arc welding power source errorNew welding start.
Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  70Err70
SUB-Code[70**] shows the error code of Fronius power source
70:main error code
**:sub error code
Arc welding power source errorCheck gas.
Confirm the Fronius’s manual.
  71Err71
SUB-Code[71**] shows the error code of Fronius power source
71:main error code
**:sub error code
Arc welding power source errorCheck the welding seam. Confirm the Fronius’s manual.
  72ErrCfg
SUB-Code[72**] shows the error code of Fronius power source
72:main error code
**:sub error code
Arc welding power source errorCheck LHSB connection. Confirm the Fronius’s manual.
  73noHost
SUB-Code[73**] shows the error code of Fronius power source
73:main error code
**:sub error code
Arc welding power source errorCheck the connection between UST and RCU and the firmware. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  74Touch
SUB-Code[74**] shows the error code of Fronius power source
74:main error code
**:sub error code
Arc welding power source errorTouch sensing mode activated – no error. Confirm the Fronius’s manual.
  75Err75
SUB-Code[75**] shows the error code of Fronius power source
75:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
  77Err77
SUB-Code[77**] shows the error code of Fronius power source
77:main error code
**:sub error code
Arc welding power source errorCheck the wire feeding alignment if it is smooth. Confirm the Fronius’s manual.
  78E-Stop
SUB-Code[78**] shows the error code of Fronius power source
78:main error code
**:sub error code
Arc welding power source errorClose the Safety circuit and activate the Error reset. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  79ErrU0
SUB-Code[79**] shows the error code of Fronius power source
79:main error code
**:sub error code
Arc welding power source errorConfirm the Fronius’s manual.
  80Err080
SUB-Code[80**] shows the error code of Fronius power source
80:main error code
**:sub error code
Arc welding power source errorCheck the connection hose pack between power source and wire feeder.
Confirm the Fronius’s manual.
  81tP7hot
SUB-Code[81**] shows the error code of Fronius power source
81:main error code
**:sub error code
Arc welding power source errorAllow the machine to cool. Confirm the Fronius’s manual.
  82ErrEHF
SUB-Code[82**] shows the error code of Fronius power source
82:main error code
**:sub error code
Arc welding power source errorAllow the external HF to cool down. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  83PHASE
SUB-Code[83**] shows the error code of Fronius power source
83:main error code
**:sub error code
Arc welding power source errorCheck the mains supply cable of the power source. Confirm the Fronius’s manual.
  100UndOpc
SUB-Code[100**] shows the error code of Fronius power source
100:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  101PrtFlt
SUB-Code[101**] shows the error code of Fronius power source
101:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  102IllOpa
SUB-Code[102**] shows the error code of Fronius power source
102:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  103IllIna
SUB-Code[103**] shows the error code of Fronius power source
103:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  104IllBus
SUB-Code[104**] shows the error code of Fronius power source
104:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  105Err105
SUB-Code[105**] shows the error code of Fronius power source
105:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  106STKOVL
SUB-Code[106**] shows the error code of Fronius power source
106:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  107STKUVL
SUB-Code[107**] shows the error code of Fronius power source
107:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  108ErrDog
SUB-Code[108**] shows the error code of Fronius power source
108:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  109ASSErt
SUB-Code[109**] shows the error code of Fronius power source
109:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.
  110EDg  1
SUB-Code[110**] shows the error code of Fronius power source
110:main error code
**:sub error code
Arc welding power source errorUpdate firmware, otherwise change the UST board. Confirm the Fronius’s manual.