Yaskawa Alarm Codes 4250 – 4299
Yaskawa Alarm Codes 4250 – 4299
4250 | MOTOWELD DIGI- TAL I/F ERROR | 1 | Error from welder 1. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
403 | SUB-Code: Error No. from welder. | Arc welding power source error | Confirm the following content. (1) LAN cable is not damaged. (2) Protocol type of the VEW01 is correct. (is MOTOWELD type?) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4251 | MOTOWELD DIGI- TAL I/F FILE# ER- ROR | 1 | Error from welder 1. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
404 | SUB-Code: Error No. from welder. | Arc welding power source error | Set the user file number 1…16. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4252 | MOTOWELD DIGI- TAL I/F CHIP ER- ROR | 1 | Error from welder 1. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
405 | SUB-Code: Error No. from welder. | Arc welding power source error | Replace the main board {Pr(MB) -024}. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4253 | MOTOWELD MA- CHINE TYP.ER- ROR1 | 1 | Error from welder 1. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
304 | SUB-Code: Error No. from welder. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4254 | MOTOWELD MA- CHINE TYP.ER- ROR2 | 1 | Error from welder 1. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
305 | SUB-Code: Error No. from welder. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4255 | MOTOWELD MA- CHINE TYP.ER- ROR3 | 1 | Error from welder 1. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
306 | SUB-Code: Error No. from welder. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4256 | MOTOWELD MA- CHINE TYP.ER- ROR4 | 1 | Error from welder 1. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
307 | SUB-Code: Error No. from welder. | Arc welding power source error | The setting of hardware or software may be not performed cor- rectly. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4257 | MOTOWELD PAN- EL SW SETTING ERROR | 1 | Error from welder 1. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
303 | SUB-Code: Error No. from welder. | Arc welding power source error | (1) Check the DIP switch setting of PR(CR) -002R1 board. (2) PR(CR) -002R1 board may be broken. Contact your YASKA- WA representative. | |||||||||||||||||||||||||||||||||||
4258 | MOTOWELD FEEDER ERROR | 1 | Error from welder 1. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
501 | SUB-Code: Error No. from welder. | Arc welding power source error | Confirm the following content. (1)The encoder cable be not damaged? (2)Isn’t there loosening of the screw of the encoder cable connec- tion terminal block? When there are a disconnection of the encoder cable or loosening of the screw, the wire feeding speed quickens abnormally, and it becomes an abnormal amount of feeding. Replace the encoder cable or fasten the screw of the terminal block. (3)Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
331 | The status of dip switch for encoder cir- cuit is different to the encoder of the feeder motor. | Arc welding power source error | (1)Confirm the feeder motor type. (2)Check the C parameter for feeder motor is correct. (3)Check the dip switch SW700 on the Main board Pr(MB). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4259 | MOTOWELD MO- TOR OVER-CUR- RENT | 1 | Error from welder 1. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and coduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
502 | SUB-Code: Error No. from welder. | Arc welding power source error | Check if the wire load becomes heavy. Make sure that the torch cable and conduit cable are not bent excessively. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4260 | MOTOWELD CPU ERROR1 | 1 | Error from welder 1. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
203 | SUB-Code: Error No. from welder. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
4261 | MOTOWELD CPU ERROR2 | 1 | Error from welder 1. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
204 | SUB-Code: Error No. from welder. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
4262 | MOTOWELD MEM- ORY ERROR1 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
205 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4263 | MOTOWELD MEM- ORY ERROR2 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
215 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4264 | MOTOWELD MEM- ORY ERROR3 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
206 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4265 | MOTOWELD MEM- ORY ERROR4 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
207 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4266 | MOTOWELD MEM- ORY ERROR5 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
208 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4267 | MOTOWELD MEM- ORY ERROR6 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
209 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4268 | MOTOWELD MEM- ORY ERROR7 | 1 | Error from welder 1. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
210 | SUB-Code: Error No. from welder. | Arc welding power source error | The data may not have been correctly saved when the welding conditions are recorded because of a power failure, etc. Reset the system after saving the changed parameters. (See the manual of MOTOWELD “4.2.10 System Reset”) If the error occurs again, the board may be broken. Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4269 | MOTOWELD STARTING SIGNAL ERROR | 1 | Error from welder 1. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
601 | SUB-Code: Error No. from welder. | Arc welding power source error | Check again the operation timing or signal cable connections. The same error may occur at momentary power failure. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4270 | MOTOWELD NO WELDING TYPE | 1 | Error from welder 1. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
602 | SUB-Code: Error No. from welder. | Arc welding power source error | Select a correct welding process in the using the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4271 | MOTOWELD VOLT.DETECT WIRE ERROR | 1 | Error from welder 1. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
702 | SUB-Code: Error No. from welder. | Arc welding power source error | (1)Check if the voltage detection wire is connected. Heck if the voltage detection line or the short-circuit cap is connected to the CON7 of the MOTOWELD. (2)Check that the contact tip does not contact the work piece to be welded. Set the contact tip so as not to contact the work piece. (3)Temporary power failure may have occurred. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4272 | MOTOWELD SAFTY-CIRCUIT ERROR | 1 | Error from welder 1. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
101 | SUB-Code: Error No. from welder. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4273 | MOTOWELD IGBT SHORT CIRCUIT | 1 | Error from welder 1. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
104 | SUB-Code: Error No. from welder. | Arc welding power source error | Replace the IGBT device (Part code AJ0EL3870). | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4274 | MOTOWELD VOLT- AGE DETECTOR ERROR | 1 | Error from welder 1. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
110 | SUB-Code: Error No. from welder. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4275 | MOTOWELD AUX. CIRCUIT OV. CUR- RENT | 1 | Error from welder 1. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
111 | SUB-Code: Error No. from welder. | Arc welding power source error | The board may be broken. Contact your YASKAWA representa- tive. | |||||||||||||||||||||||||||||||||||
4276 | MOTOWELD DSP ADC ERROR | 1 | Error from welder 1. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
119 | SUB-Code: Error No. from welder. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4277 | MOTOWELD OUT- SIDE OF CURR.SETTING(H) | 1 | Error from welder 1. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
790 | SUB-Code: Error No. from welder. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4278 | MOTOWELD OUT- SIDE OF CURR.SETTING(L) | 1 | Error from welder 1. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
791 | SUB-Code: Error No. from welder. | Arc welding power source error | (1) Check if the selection of motor is correct, or confirm the set- tings of C parameter C09. (2) Check that the welding wire does not slip, or the wire is fed as instructed by the feeding command. (3) Check that the wire stick out is not excessively short or long. (4) Check that the range set in C parameter C29 is not too narrow. (5) Check if the wire, shielding, etc. are correctly set. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4279 | MOTOWELD MO- MENTARY OVER-CURR | 1 | Error from welder 1. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
108 | SUB-Code: Error No. from welder. | Arc welding power source error | (1) Check that short-circuit or the earth grounded of the output ca- ble. (2)May be power circuit broken. Contact your YASKAWA repre- sentative. | |||||||||||||||||||||||||||||||||||
4280 | MOTOWELD OVER-VOLTAGE | 1 | Error from welder 1. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
109 | SUB-Code: Error No. from welder. | Arc welding power source error | Contact your YASKAWA representative. | |||||||||||||||||||||||||||||||||||
4281 | MOTOWELD +15V POWER SUPPLY ERROR | 1 | Error from welder 1. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
704 | SUB-Code: Error No. from welder. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4282 | MOTOWELD POW- ER SUPPLY ER- ROR | 1 | Error from welder 1. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
705 | SUB-Code: Error No. from welder. | Arc welding power source error | Replace the switching power supply unit. (Service parts code:AJ0E35055) | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4283 | MOTOWELD ILLE- GAL WELD TYPE | 1 | Error from welder 1. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
2 | Error from welder 2. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
3 | Error from welder 3. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4 | Error from welder 4. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | Error from welder 5. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
6 | Error from welder 6. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
7 | Error from welder 7. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
8 | Error from welder 8. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
406 | A wrong welding pro- cess is set in the welding user file. | Arc welding power source error | Confirm the welding process setting in the welding user file. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
407 | A welding type is not set in a user file of the MOTOWELD. | Arc welding power source error | Set a welding type to user file of MOTOWELD. The user file can setup in the editor screen for ARC START CONDITION FILE or ARC END CONDITION FILE of the DX200. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4284 | MOTOWELD SOFTWARE MUL- FUNCTION | 310 | The version of the data base is not suit- able for the software of the welding power source. | Arc welding power source error | Load the suitable database. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
311 | The version informa- tion of the PLD on the main board Pr(MB) is wrong. | Arc welding power source error | Replace the main board {Pr(MB) -030}. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
312 | The version of the firmware of front pan- el is not suitable for the software of the main board Pr(MB). | Arc welding power source error | Replace the front panel {Panel-CR30 unit}. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
316 | The check sum of the PLD on the main board Pr(MB) is wrong. | Arc welding power source error | Replace the main board {Pr(MB) -030}. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
317 | The program or data base was load by the ethernet. | Arc welding power source error | Reboot the power source. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
318 | The check sum error of loading data. | Arc welding power source error | (1)Do not turn off the power source and reload the data. (2)In case of turn off and reboot was OK, reload the data. (3)In case of turn off and reboot was NG, load the data by special loading tool. (4)Other case of step 1,2,3, replace the main board Pr(MB)-030. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
400 | Watch dog error of the PLD. | Arc welding power source error | (1) Reboot the power source. (2) Replace the main board {Pr(MB) -030}. | |||||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4285 | MOTOWELD MA- CHINE SETTING ERROR | 320 | The machine type is wrong. | Arc welding power source error | (1) Check the connection between front panel and main board. (2) Check the status of dip switch (SW301) on the front panel. (3) Replace the front panel. (4) Replace the main board. | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4286 | MOTOWELD CUR- RENT CLASS ER- ROR | 330 | The current class 350A / 500A setting is wrong. | Arc welding power source error | (1) Confirm the power source class which of 350A or 500A. (2) Switch a status of dip switch SW600 which of 350A or 500A. (3)Change the software which for correct current class. | |||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
other | If the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure). | |||||||||||||||||||||||||||||||||||||
4290 | TPS:ERROR | 1 | no Prg SUB-Code[1**] shows the error code of Fronius power source 1:main error code **:sub error code | Arc welding power source error | Select a pre-programmed program. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||
2 | ts1 SUB-Code[2**] shows the error code of Fronius power source 2:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
3 | ts2 SUB-Code[3**] shows the error code of Fronius power source 3:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
4 | ts3 SUB-Code[4**] shows the error code of Fronius power source 4:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
5 | tp1 SUB-Code[5**] shows the error code of Fronius power source 5:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
6 | tp2 SUB-Code[6**] shows the error code of Fronius power source 6:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
7 | tp3 SUB-Code[7**] shows the error code of Fronius power source 7:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
8 | tp4 SUB-Code[8**] shows the error code of Fronius power source 8:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
9 | tp5 SUB-Code[9**] shows the error code of Fronius power source 9:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
10 | tp6 SUB-Code[10**] shows the error code of Fronius power source 10:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
11 | Errtf1 SUB-Code[11**] shows the error code of Fronius power source 11:main error code **:sub error code | Arc welding power source error | Change the thermo-sensor on the sec. side. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
12 | Errtf2 SUB-Code[12**] shows the error code of Fronius power source 12:main error code **:sub error code | Arc welding power source error | Change the thermo-sensor on the sec. side. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
13 | Errtf3 SUB-Code[13**] shows the error code of Fronius power source 13:main error code **:sub error code | Arc welding power source error | Check cable tree of temperature sensors. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
14 | Errtf4 SUB-Code[14**] shows the error code of Fronius power source 14:main error code **:sub error code | Arc welding power source error | Only for MagicWave power source. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
15 | Errtf5 SUB-Code[15**] shows the error code of Fronius power source 15:main error code **:sub error code | Arc welding power source error | Check cable tree of temperature sensors. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
16 | Errtf6 SUB-Code[16**] shows the error code of Fronius power source 16:main error code **:sub error code | Arc welding power source error | Change BPS pc-board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
17 | DSPE05 SUB-Code[17**] shows the error code of Fronius power source 17:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
18 | ErrbPS SUB-Code[18**] shows the error code of Fronius power source 18:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board or otherwise change the BPS board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
19 | Err IP SUB-Code[19**] shows the error code of Fronius power source 19:main error code **:sub error code | Arc welding power source error | Change the BPS board. Change the secondary diode. Change the welding transformer. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
20 | DSPAxx SUB-Code[20**] shows the error code of Fronius power source 20:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
21 | DSPExx SUB-Code[21**] shows the error code of Fronius power source 21:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
22 | ErrEPF SUB-Code[22**] shows the error code of Fronius power source 22:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
23 | Err23.x SUB-Code[23**] shows the error code of Fronius power source 23:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
24 | Err24.x SUB-Code[24**] shows the error code of Fronius power source 24:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
25 | Err25.x SUB-Code[25**] shows the error code of Fronius power source 25:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
26 | Err26.x SUB-Code[26**] shows the error code of Fronius power source 26:main error code **:sub error code | Arc welding power source error | Check whether the CfgMem has good contact to the connecting cables and in the plug. Re-crimp if necessary. If this does not help, remove and send to Fronius Austria, together with details of the series number of the machine. Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
27 | Err027 SUB-Code[27**] shows the error code of Fronius power source 27:main error code **:sub error code | Arc welding power source error | Measure the +24VDC of NT 24. Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
28 | Err028 SUB-Code[28**] shows the error code of Fronius power source 28:main error code **:sub error code | Arc welding power source error | Change the cooling-unit temperature sensor. Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
29 | DSPC SUB-Code[29**] shows the error code of Fronius power source 29:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
30 | EFd SUB-Code[30**] shows the error code of Fronius power source 30:main error code **:sub error code | Arc welding power source error | Check the wire-feed system. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
31 | Err31 SUB-Code[31**] shows the error code of Fronius power source 31:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
32 | EcF SUB-Code[32**] shows the error code of Fronius power source 32:main error code **:sub error code | Arc welding power source error | Install correct primary BPS power module. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
33 | tSt SUB-Code[33**] shows the error code of Fronius power source 33:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
34 | Errtf7 SUB-Code[34**] shows the error code of Fronius power source 34:main error code **:sub error code | Arc welding power source error | Change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
35 | DSP KL SUB-Code[35**] shows the error code of Fronius power source 35:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
36 | DSPnSy SUB-Code[36**] shows the error code of Fronius power source 36:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
37 | US POL SUB-Code[37**] shows the error code of Fronius power source 37:main error code **:sub error code | Arc welding power source error | Change over the polarity of the two cables otherwise change the UST board Confirm the Fronius’s manual | |||||||||||||||||||||||||||||||||||
38 | -Stop- SUB-Code[38**] shows the error code of Fronius power source 38:main error code **:sub error code | Arc welding power source error | Deactivate the -Stop- by input -RobotReady- and activate briefly -SourceErrorReset-. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
39 | NoH2O SUB-Code[39**] shows the error code of Fronius power source 39:main error code **:sub error code | Arc welding power source error | Check the coolant level and (if appropriate) the coolant return- flow rate If necessary, clean the coolant filter. Rate-of-flow watchdog may be defective. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
49 | Err049 SUB-Code[49**] shows the error code of Fronius power source 49:main error code **:sub error code | Arc welding power source error | Check the mains power supply. Check all 3 phases. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
50 | Err050 SUB-Code[50**] shows the error code of Fronius power source 50:main error code **:sub error code | Arc welding power source error | Disconnect NT60 or change/check NT24/UST/BPS/intermediate circuit capacitors. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
51 | Err051 SUB-Code[51**] shows the error code of Fronius power source 51:main error code **:sub error code | Arc welding power source error | Mains voltage too low or NT 24 defective. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
52 | Err052 SUB-Code[52**] shows the error code of Fronius power source 52:main error code **:sub error code | Arc welding power source error | Mains voltage too high or NT 24 defective. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
53 | ErrPE SUB-Code[53**] shows the error code of Fronius power source 53:main error code **:sub error code | Arc welding power source error | Low-resistance connection between secondary and machine housing find out the cause. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
54 | Err054 SUB-Code[54**] shows the error code of Fronius power source 54:main error code **:sub error code | Arc welding power source error | Increase the bbc (burn-back control) Switch off “Wire stick” in the set-up menu After the end of welding, make sure that the wire does not collide with the workpiece when the torch is retracted. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
55 | NoIGn SUB-Code[55**] shows the error code of Fronius power source 55:main error code **:sub error code | Arc welding power source error | Set a lower Ito value Keep the torch stand-off distance smaller before ignition. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
56 | Err056 SUB-Code[56**] shows the error code of Fronius power source 56:main error code **:sub error code | Arc welding power source error | Check how much wire is left on the spool If necessary, change the spool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
57 | NoGAS SUB-Code[57**] shows the error code of Fronius power source 57:main error code **:sub error code | Arc welding power source error | Check what volume of gas is still available. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
58 | NoArc SUB-Code[58**] shows the error code of Fronius power source 58:main error code **:sub error code | Arc welding power source error | Check the seam. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
59 | Err059 SUB-Code[59**] shows the error code of Fronius power source 59:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
60 | Err060 SUB-Code[60**] shows the error code of Fronius power source 60:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
61 | ErrArc SUB-Code[61**] shows the error code of Fronius power source 61:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
62 | Err062 SUB-Code[62**] shows the error code of Fronius power source 62:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
63 | EIF SUB-Code[63**] shows the error code of Fronius power source 63:main error code **:sub error code | Arc welding power source error | Check the interface configuration. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
64 | Errtf8 SUB-Code[64**] shows the error code of Fronius power source 64:main error code **:sub error code | Arc welding power source error | Change the thermo-sensor of the cooling unit. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
65 | hotH2O SUB-Code[65**] shows the error code of Fronius power source 65:main error code **:sub error code | Arc welding power source error | Cool down the cooling liquid. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
66 | tJo SUB-Code[66**] shows the error code of Fronius power source 66:main error code **:sub error code | Arc welding power source error | Allow the JOBMaster torch to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
67 | ErrtJo SUB-Code[67**] shows the error code of Fronius power source 67:main error code **:sub error code | Arc welding power source error | Change JOBMaster pc-board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
68 | Err068 SUB-Code[68**] shows the error code of Fronius power source 68:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
69 | Err069 SUB-Code[69**] shows the error code of Fronius power source 69:main error code **:sub error code | Arc welding power source error | New welding start. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
70 | Err70 SUB-Code[70**] shows the error code of Fronius power source 70:main error code **:sub error code | Arc welding power source error | Check gas. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
71 | Err71 SUB-Code[71**] shows the error code of Fronius power source 71:main error code **:sub error code | Arc welding power source error | Check the welding seam. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
72 | ErrCfg SUB-Code[72**] shows the error code of Fronius power source 72:main error code **:sub error code | Arc welding power source error | Check LHSB connection. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
73 | noHost SUB-Code[73**] shows the error code of Fronius power source 73:main error code **:sub error code | Arc welding power source error | Check the connection between UST and RCU and the firmware. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
74 | Touch SUB-Code[74**] shows the error code of Fronius power source 74:main error code **:sub error code | Arc welding power source error | Touch sensing mode activated – no error. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
75 | Err75 SUB-Code[75**] shows the error code of Fronius power source 75:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
77 | Err77 SUB-Code[77**] shows the error code of Fronius power source 77:main error code **:sub error code | Arc welding power source error | Check the wire feeding alignment if it is smooth. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
78 | E-Stop SUB-Code[78**] shows the error code of Fronius power source 78:main error code **:sub error code | Arc welding power source error | Close the Safety circuit and activate the Error reset. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
79 | ErrU0 SUB-Code[79**] shows the error code of Fronius power source 79:main error code **:sub error code | Arc welding power source error | Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
80 | Err080 SUB-Code[80**] shows the error code of Fronius power source 80:main error code **:sub error code | Arc welding power source error | Check the connection hose pack between power source and wire feeder. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
81 | tP7hot SUB-Code[81**] shows the error code of Fronius power source 81:main error code **:sub error code | Arc welding power source error | Allow the machine to cool. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
82 | ErrEHF SUB-Code[82**] shows the error code of Fronius power source 82:main error code **:sub error code | Arc welding power source error | Allow the external HF to cool down. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
83 | PHASE SUB-Code[83**] shows the error code of Fronius power source 83:main error code **:sub error code | Arc welding power source error | Check the mains supply cable of the power source. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
100 | UndOpc SUB-Code[100**] shows the error code of Fronius power source 100:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
101 | PrtFlt SUB-Code[101**] shows the error code of Fronius power source 101:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
102 | IllOpa SUB-Code[102**] shows the error code of Fronius power source 102:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
103 | IllIna SUB-Code[103**] shows the error code of Fronius power source 103:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
104 | IllBus SUB-Code[104**] shows the error code of Fronius power source 104:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
105 | Err105 SUB-Code[105**] shows the error code of Fronius power source 105:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
106 | STKOVL SUB-Code[106**] shows the error code of Fronius power source 106:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
Alarm No. | Alarm Name | SUB- Code | Meaning | Cause | Remedy | |||||||||||||||||||||||||||||||||
107 | STKUVL SUB-Code[107**] shows the error code of Fronius power source 107:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
108 | ErrDog SUB-Code[108**] shows the error code of Fronius power source 108:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
109 | ASSErt SUB-Code[109**] shows the error code of Fronius power source 109:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. | |||||||||||||||||||||||||||||||||||
110 | EDg 1 SUB-Code[110**] shows the error code of Fronius power source 110:main error code **:sub error code | Arc welding power source error | Update firmware, otherwise change the UST board. Confirm the Fronius’s manual. |