Yaskawa Alarm Codes 4000 – 4099

Yaskawa Alarm Codes 4000 – 4099

Home > Yaskawa > Alarm Codes > Alarm Codes 4000 – 4099

Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4000MEMORY ERROR (TOOL FILE) Sub Code: Tool num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the tool file in MAINTE- NANCE mode, and then load the tool file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4001MEMORY ERROR
(USER COORD FILE)
 Sub Code: User coor- dinate numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the tool file in MAINTE- NANCE mode, and then load the tool file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4002MEMORY ERROR
(SV MON SIGNAL FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the tool file in MAINTE- NANCE mode, and then load the tool file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4003MEMORY ERROR (WEAVING FILE) Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the weaving condition file in MAINTENANCE mode, and then load the weaving condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4004MEMORY ERROR (HOME POS FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the home positioning file in MAINTENANCE mode, and then load the home positioning file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4005MEMORY ERROR
(SECOND HOME POS)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the second home position- ing file in MAINTENANCE mode, and then load the second home positioning file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4006MEMORY ERROR
(POWER SOURCE COND)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the arc welding Power Source condition file in MAINTENANCE mode, and then load the arc welding Power Source condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4007MEMORY ERR
(ARC START COND FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the arc start condition file in MAINTENANCE mode, and then load the arc start condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4008MEMORY ERROR
(ARC END COND FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the arc end condition file in MAINTENANCE mode, and then load the arc end condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4009MEMORY ERROR
(ARC AUX COND FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the arc auxiliary condition file in MAINTENANCE mode, and then load the arc auxiliary con- dition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4010MEMORY ERROR
(COM-ARC COND FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the COM-ARC condition file in MAINTENANCE mode, and then load the COM-ARC condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4011MEMORY ER- ROR(FILE DATA)230The memory for the gun detail setting file is damaged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the gun detail setting file in MAINTENANCE mode, and then load the gun detail setting file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  231The memory for the spot management file is damagedData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the spot management file in MAINTENANCE mode, and then load the spot management file saved in the external memory device.
YCP21 board failure (1) Reset
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  232The memory for the spot welder I/F file is damaged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the spot welder I/F file in MAINTENANCE mode, and then load the spot welder I/F file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  233The memory for the manual press condi- tion file is damaged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the manual press condition file in MAINTENANCE mode, and then load the manual press condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  240The memory for the wear detection base position file is dam- aged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the wear detection base po- sition file in MAINTENANCE mode, and then load the wear detec- tion base position file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  243The memory for the learning control I/O al- location file is dam- aged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the learning control I/O al- location file in MAINTENANCE mode, and then load the learning control I/O allocation file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  261The memory for the IOSPDCTRL setup file is damaged.Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the IOSPDCTRL setup file in MAINTENANCE mode, and then load the IOSPDCTRL setup file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4012MEMORY ERROR
(LINK SERVO- FLOAT)
 SUB-Code: Condi- tion file numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the link SERVO float condi- tion file in MAINTENANCE mode, and then load the link SERVO float condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe.
Replace the YCP21 board, and then insert the CF card which in- serted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4013MEMORY ERROR
(LINEAR SERVO- FLOAT)
 Sub Code: Condition file numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the linear servo float condi- tion file in MAINTENANCE mode, and then load the linear servo float condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4014MEMORY ERROR
(ROBOT CALIB FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the file for calibration be- tween manipulators in MAINTENANCE mode, and then load the file for calibration between manipulators saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4017MEMORY ERROR
(POWER SRC USER-DEF)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the Power Source user defi- nition file in MAINTENANCE mode, and then load the Power Source user definition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4018MEMORY ERR
(LADDER PRG FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the ladder program file in MAINTENANCE mode, and then load the ladder program file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4019MEMORY ERROR
(CUTTING COND FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the cutting condition file in MAINTENANCE mode, and then load the cutting condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4020MEMORY ERROR
(OPERATION ORI- GIN)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the work home position file in MAINTENANCE mode, and then load the work home position file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4021MEMORY ERROR
(CONVEYOR COND FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the conveyor condition file in MAINTENANCE mode, and then load the conveyor condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4022MEMORY ERROR
(PAINT SPECIAL FILE)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the paint special file in MAINTENANCE mode, and then load the paint special file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4023MEMORY ERROR (PAINT COND FILE) Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the paint condition file in MAINTENANCE mode, and then load the paint condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4024MEMORY ERR
(WRIST WEAV AMP FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the wrist weaving amplitude file in MAINTENANCE mode, and then load the wrist weaving am- plitude file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4025MEMORY ERROR
(INTERRUPT JOB FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the interrupt JOB file in MAINTENANCE mode, and then load the interrupt JOB file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4028MEMORY ERR
(SENSOR MON COND FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the sensor monitoring con- dition file in MAINTENANCE mode, and then load the sensor monitoring condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4030MEMORY ERR
(PRESS COND DATA FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the press condition file in MAINTENANCE mode, and then load the press condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4031MEMORY ERROR
(SPOT GUN COND FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the gun condition file in MAINTENANCE mode, and then load the gun condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4032MEMORY ERROR
(SPOT WELDER COND)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the spot welding gun con- dition file in MAINTENANCE mode, and then load the spot weld- ing gun condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4033MEMORY ERROR
(GUN PRESSURE FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the gun pressure file in MAINTENANCE mode, and then load the gun pressure file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4034MEMORY ERR
(ANTICIPATION OT FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the anticipation output (OT) file in MAINTENANCE mode, and then load the anticipation out- put (OT) file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4035MEMORY ERR
(ANTICIPATION OG FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the anticipation output (OG) file in MAINTENANCE mode, and then load the anticipation out- put (OG) file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4036MEMORY ERROR (WEARING FILE) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the wear amount file in MAINTENANCE mode, and then load the wear amount file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4037MEMORY ERROR
(STROKE POSI- TION)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the FULL/SHORT OPEN position setting file in MAINTENANCE mode, and then load the FULL/SHORT OPEN position setting file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4038MEMORY ERROR (PRESSURE FILE) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the dry-spotting pressure file in MAINTENANCE mode, and then load the dry-spotting pres- sure file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4039MEMORY ERROR (FORM CUT FILE) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the form cut file in MAINTE- NANCE mode, and then load the form cut file saved in the exter- nal memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4040MEMORY ERROR
(SHOCK LEVEL FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the shock level file in MAIN- TENANCE mode, and then load the shock level file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4041MEMORY ERROR
(SPOT IO AL- LOCTE FL)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the spot I/O allocation file in MAINTENANCE mode, and then load the spot I/O allocation file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4042MEMORY ERROR (VISION FILE) Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the vision condition file in MAINTENANCE mode, and then load the vision condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4043MEMORY ERROR
(VISION CALIBRA- TION)
 Sub Code: Page numberData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the vision calibration file in MAINTENANCE mode, and then load the vision calibration file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4044MEMORY ERROR
(WELD PULSE COND)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the welding pulse condition file in MAINTENANCE mode, and then load the welding pulse condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4045MEMORY ERROR
(WELD PULSE SE- LECT)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the welding pulse selection file in MAINTENANCE mode, and then load the welding pulse se- lection file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4046MEMORY ERR
(CONVEYOR CAL- IB FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the conveyor calibration file in MAINTENANCE mode, and then load the conveyor calibration file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4047MEMORY ERROR
(MACRO DEFINI- TION FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the macro definition file in MAINTENANCE mode, and then load the macro definition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4048MEMORY ERROR
(SERVO S-GUN FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the sealer gun characteris- tics file in MAINTENANCE mode, and then load the sealer gun characteristics file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4049MEMORY ERROR
(PASTE QUAN.COMP FL)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the painting amount correc- tion file in MAINTENANCE mode, and then load the painting amount correction file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4050MEMORY ERR
(AXIS I/O ALLOC FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the axis motion I/O alloca- tion file in MAINTENANCE mode, and then load the axis motion I/O allocation file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4051MEMORY ERR
(GUN COND. AUX. FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the gun characteristics aux- iliary file in MAINTENANCE mode, and then load the gun charac- teristics auxiliary file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4052MEMORY ERROR
(TOOL INTERFER- ENCE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the tool interference file in MAINTENANCE mode, and then load the tool interference file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4053MEMORY ERROR
(PAINT SYS CON- FIG.)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the painting system setting file in MAINTENANCE mode, and then load the painting system setting file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4054MEMORY ERROR
(PAINTING SPE- CIAL)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the painting device charac- teristics file in MAINTENANCE mode, and then load the painting device characteristics file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4055MEMORY ERROR
(CCV-PAINT TA- BLE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the painting CCV file in MAINTENANCE mode, and then load the painting CCV file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4056MEMORY ERROR
(PLUG VOLUME FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the painting filling file in MAINTENANCE mode, and then load the painting filling file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4057MEMORY ERROR (EVB GUN COND) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the EVB gun condition file in MAINTENANCE mode, and then load the EVB gun condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4058MEMORY ERROR
(EVB TURBIN COND)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the EVB turbine condition file in MAINTENANCE mode, and then load the EVB turbine con- dition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4059MEMORY ERROR (EVB PAINT COND) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the EVB paint condition file in MAINTENANCE mode, and then load the EVB paint condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4060MEMORY ERROR
(CLEARANCE FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the clearance file in MAIN- TENANCE mode, and then load the clearance file saved in the ex- ternal memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4061MEMORY ERROR
(GAUGE SENSOR FILE)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the gauging sensor condi- tion file in MAINTENANCE mode, and then load the gauging sen- sor condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4062MEMORY ERROR (LNR SCALE FILE) Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the linear scale condition file in MAINTENANCE mode, and then load the linear scale con- dition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4063MEMORY ERR
(CONVEYOR COND SUPP.)
 Sub Code: File num- berData error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the conveyor condition aux- iliary file in MAINTENANCE mode, and then load the conveyor condition auxiliary file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4064MEMORY ERR
(WEAV SYNC WELD FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the weaving synchronizing welding condition file in MAINTENANCE mode, and then load the weaving synchronizing welding condition file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4065MEMORY ERROR (I/F PANEL FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the I/F panel file in MAIN- TENANCE mode, and then load the I/F panel file saved in the ex- ternal memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4069MEMORY ERR
(PALLETIZE COND FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the palletize condition file in MAINTENANCE mode, and then load the palletize condition file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4070MEMORY ERROR
(LASER TRACKING START FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the laser tracking welding start file in MAINTENANCE mode, and then load the laser track- ing welding start file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4071MEMORY ERROR
(LASER TRACKING END FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the laser tracking welding end file in MAINTENANCE mode, and then load the laser tracking welding end file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4072MEMORY ERROR
(LASER TRACKING TRACK START FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the laser tracking track start file in MAINTENANCE mode, and then load the laser tracking track start file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4073MEMORY ERROR
(LASER TRACKING SET FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the laser tracking welding set file in MAINTENANCE mode, and then load the laser tracking welding set file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4074MEMORY ERROR
(LASER TRACKING TRACK SET FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the laser tracking track set file in MAINTENANCE mode, and then load the laser tracking track set file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4075MEMORY ERROR
(CONDITION FILE OF CORRE- SPONDING TO LA- SER TRACKING GAP)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the condition file of corre- sponding to laser tracking gap in MAINTENANCE mode, and then load the condition file of corresponding to laser tracking gap saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4080MEMORY ERR
(MUTUAL WAIT SET FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the mutual wait set file in MAINTENANCE mode, and then load the mutual wait set file saved in the external memory device.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4081MEMORY ERR
(INTERF. PREDICT FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the mutual wait set file in MAINTENANCE mode, and then load the interference predict file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4082INTERF. PREDICT DETECT  Operation mistake or teaching mistake(1) Reset the alarm.
(2)Pull the manipulators away each other.
(3)If this alarm occurred during test run or playback operation, change the teaching points.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4083INTERF. PREDICT COMM ERROR SUB-Code
0000_0000_0000_00
10:DX200 received an error response from the interference predict server.
0001_0000_0000_00
01:No response for the interference check start request was returned from the interference predict server.
Connection failure(1) Reset the alarm.
(2) Check the connection between interference predict server and DX200.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4083INTERF. PREDICT COMM ERROR 0001_0000_0000_00
10:No response for the current position acquisition request was returned from the interference predict server.
0001_0000_0000_00
11:DX200 received an error response for the interference check start request from the interference predict server.
Connection failure(1) Reset the alarm.
(2) Check the connection between interference predict server and DX200.
    Setting error(1) Reset the alarm.
(2)Check each network setting for the robot controller and the in- terference predict server.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4084ROBOT SYNC. ER- ROR SubCode 0000_0000_0000_00
01:No response was returned from the mu- tual wait target.
0000_0000_0000_00
10:An error occurred in the communication with the mutual wait target during the exe- cution of FN591.
0000_0000_0000_00
11:An error occurred in the communication with the mutual wait target during the exe- cution of FN591.
0000_0000_0000_01
00:FN591 execution cancel was received even though FN591 execution notice hadn’t been received from the mutual wait target.
0000_0000_0000_01
01:FN591 execution cancel error from the mutual wait target was received.
0000_0000_0001_00
00:The mutual wait manipulator No. of the FN591 is abnormal.
0000_0000_0010_00
00:FN591 was doubly executed.
0000_0000_0011_00
00:FN591 execution notice from the mutu- al wait target was re-
Connection failureSubCode 0000_0000_0000_0001
0000_0000_0000_0010
0000_0000_0000_0011
0000_0000_0000_0100
0000_0000_0000_0101
0000_0000_0011_0000
0000_0000_0100_0000
(1) Reset the alarm.
(2)Check the communication connection with the mutual wait tar- get.
      
4084ROBOT SYNC. ER- ROR 0000_0000_0100_00
00:FN591 execution notice error from the mutual wait target was received.
Connection failureSubCode 0000_0000_0000_0001
0000_0000_0000_0010
0000_0000_0000_0011
0000_0000_0000_0100
0000_0000_0000_0101
0000_0000_0011_0000
0000_0000_0100_0000
(1) Reset the alarm.
(2)Check the communication connection with the mutual wait tar- get.
    HUB failureSubCode 0000_0000_0000_0001
0000_0000_0000_0010
0000_0000_0000_0011
0000_0000_0000_0100
0000_0000_0000_0101
0000_0000_0011_0000
0000_0000_0100_0000
(1) Reset the alarm.
(2)Check the communication connection with the mutual wait tar- get.
    Setting errorSubCode 0000_0000_0000_0001
(1) Reset the alarm.
(2)Check the contents of the mutual wait setting file.
(3)Check the network setting of the mutual wait target.
    Operation mistakeSubCode 0000_0000_0000_0100
0000_0000_0000_0101
(1) Reset the alarm.
(2)Check if FN591execution is aborted when FN591 execution has been mutually established. In this case, this alarm may occur due to communication time lag.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Setting errorSubCode 0000_0000_0001_0000
(1) Reset the alarm.
(2)Check the mutual wait manipulator No. of the FN591.
    Software operation error occurredSubCode 0000_0000_0010_0000
0000_0000_0011_0000
0000_0000_0100_0000
(1) Reset the alarm.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4085MEMORY ERR
(INTERF. HISTORY FILE)
  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the mutual wait set file in MAINTENANCE mode, and then load the interference history file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    other(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4086MEMORY ERROR (YSF SET FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the ysf set file in MAINTE- NANCE mode, and then load the ysf set file saved in the external memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4087MEMORY ERROR (YSF TMR FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the ysf timer file in MAIN- TENANCE mode, and then load the ysf timer file saved in the ex- ternal memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4088MEMORY ERROR (YSF LOGIC FILE)  Data error(1) Reset the alarm.
(2) If the alarm occurs again, initialize the ysf logic file in MAINTE- NANCE mode, and then load the ysf logic file saved in the exter- nal memory device.
    YCP21 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    YIF01 board failure(1) Reset the alarm.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4099DC 24V POWER SUPPLY FAILURE (YPS)  YPS21 unit failure(1) Reset the alarm.
(2) If the alarm occurs again, turn the power OFF then back ON.
(3) If the alarm occurs again, replace the following unit.
∙YPS21 unit
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Short circuit or ground fault(1) Reset the alarm.
(2) If the alarm occurs again, check the connection and inserting state of the following cables and connectors.
Check the insertion, connection, Short circuit or ground fault of the followings.
∙YFC22-CN219(81,82,92,93 : +24V2U3)
∙YFC22-CN219(83,84,94,95 : 024V2)
∙YIO-CN306,CN307,CN308,CN309
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).