Fanuc MENT Alarm Codes

Home > Fanuc > Alarm CodesMENT Alarm Codes

Fanuc MENT Alarm Codes

MENT-000 SYSTEM ME-NET system error
Cause: System internal error.
Remedy: Press RESET. If the error is not cleared, document the events that led to the error and call
your FANUC Robotics technical representative.
________________________________________________________________
MENT-001 WARN ME-NET PCB not installed
Cause: The ME-NET board is not installed.
Remedy: Install the ME-NET board.
________________________________________________________________
MENT-002 SYSTEM ME-NET PCB abnormal
Cause: The ME-NET board is abnormal.
Remedy: Check ME-NET board.
________________________________________________________________
MENT-003 SYSTEM Communication CPU ROM abnormal
Cause: Communication CPU ROM is abnormal.
Remedy: Check the ME-NET board.
________________________________________________________________
MENT-004 SYSTEM Communication CPU RAM abnormal
Cause: Communication CPU RAM is abnormal.
Remedy: Check the ME-NET board.
________________________________________________________________
MENT-005 SYSTEM Communication CPU LSI abnormal
Cause: Communication CPU RAM is abnormal.
Remedy: Check ME-NET board
________________________________________________________________
MENT-006 SYSTEM More than one taken occured
Cause: More than one taken occured.
Remedy: Check ME-NET board
________________________________________________________________
MENT-007 SYSTEM Duplicate address was detected
Cause: A duplicate address was detected.
Remedy: Check the ME-NET board
________________________________________________________________
MENT-008 SYSTEM My station Transmitter broke down
Cause: The station Transmitter broke down.
Remedy: Check the ME-NET board
________________________________________________________________
MENT-009 SYSTEM Taken not come around
Cause: Taken not come around.
Remedy: Check ME-NET board
________________________________________________________________
MENT-010 STOP Type 3 buffer overflow
Cause: A Type 3 buffer overflow.
Remedy: Check ME-NET board
________________________________________________________________
MENT-011 STOP Data-link TX length abnormal
Cause: The Data-link TX length is abnormal.
Remedy: Check the ME-NET’s system variable.
________________________________________________________________
MENT-012 STOP Relay-link TX length abnormal
Cause: The Relay-link TX length is abnormal.
Remedy: Check ME-NET’s system variable.
________________________________________________________________
MENT-013 STOP Register-link TX length abnormal
Cause: The register-link TX length is abnormal.
Remedy: Check ME-NET’s system variable.
________________________________________________________________
MENT-014 STOP Relay-link RX offset abnormal
Cause: The Relay-link RX offset is abnormal.
Remedy: Check ME-NET’s system variable.
________________________________________________________________
MENT-015 STOP Register-link RX offset abnormal
Cause: The register-link RX offset is abnormal.
Remedy: Check the ME-NET system variable.
________________________________________________________________
MENT-016 STOP RX frame ID abnormal
Cause: The RX frame ID is abnormal.
Remedy: Check ME-NET’s system variable.
________________________________________________________________
MENT-017 STOP Communication CPU no response
Cause: Even if 60 seconds passes, a logical link was not able to be joined.
Remedy: Check the ME-NET board
________________________________________________________________
MENT-018 STOP Frame length error
Cause: The construction of the media is defective
Remedy: Improve the construction of the media
________________________________________________________________
MENT-019 STOP Media defective
Cause: The construction of the media is defective
Remedy: Improve the construction of the media