Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4200SYSTEM ERROR (FILE DATA) SUB-Code 01 to 50: Signifies the internal software errorData error(1) Reset the alarm.
(2) If the alarm occurs again, turn the controller power OFF and then ON to check the operation.
(3) If the alarm occurs again, initialize the appropriate data in MAINTENANCE mode, and then load the data saved in the exter- nal memory device.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4201SYSTEM ERROR (JOB)-1An error occurred during the access to a JOB in parameter specifications.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -2Access time exceed- ed the limit during the access to a JOB.Software operation error occurredReset the alarm, and then try again.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -3The access to a JOB could not be per- formed with the spec- ified JOB name.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -4A JOB was newly cre- ated with the same name of the JOB al- ready specified in the memory.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -5A JOB was newly cre- ated with the same name of the JOB al- ready specified in the memory.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -6The allowable JOB registration area (memory) was ex- ceeded.Setting error(1) Check the following settings.
∙Delete unused JOBs.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -7A JOB that did not ex- ist in the memory was specified.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -8An attempt was made to change the con- tents for the JOB pro- hibited from being edited.Setting error(1) Check the following settings.
∙Release the prohibition.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -9An error occurred during the access to a JOB in handle value.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -10An error occurred in JOB data control sys- tem.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -11An error occurred in sequence number of the accessed JOB.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -12An error occurred in step number of the accessed JOB.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -13A JOB specified at JOB search did not exist in the memory.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -14There was an instruc- tion that did not exist in a JOB because of inconsistency of the system software.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -16Unused handles were lacking when an at- tempt was made to open a JOB.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -18The number of in- structions added to a JOB exceeded 9999.Setting error(1) Check the following settings.
∙Delete unnecessary instructions and add new instructions again.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -19The number of steps added to a JOB ex- ceeded 9999.Setting error(1) Check the following settings.
Delete unnecessary steps and add new steps again.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -22JOB information was not able to be ex- panded.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -23JOB information was not able to be ac- quired.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -24An error occurred in cluster control.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -25Failed to read the cluster information.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -26Heap area could not be obtained.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -27The target for change is the line where edit- ing is prohibited or the comment-out line.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, deactivate the prohibit setting for the target line or delete the comment-out line.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -28A false change in the marker JOB was at- tempted.Software operation error occurred(1) Reset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -90The configuration data is damaged.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -91The FAT area is dam- aged.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -92A JOB data in the memory was de- stroyed.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4202SYSTEM ERROR (JOB)1An error occurred in parameter specifica- tions for the access to a JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2Access time exceed- ed the limit during the access to a JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Unapproved charac- ters are used for a JOB name.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4A JOB was newly cre- ated with the same name of the JOB al- ready specified in the memory.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5A JOB was newly cre- ated with the same name of the JOB al- ready specified in the memory.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6The allowable JOB registration area (memory) was ex- ceeded.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete unused JOBs.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file. In that case, delete the unused JOBs.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  7A JOB that did not ex- ist in the memory was specified.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  8An attempt was made to change the con- tents for the JOB pro- hibited from being edited.Setting error(1) Check the following settings.
∙Setting of EDIT LOCK in JOB header screen
If the JOB is protected from editing, release the prohibition.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Software operation error occurred(1) Reset the alarm.
(2)If you edit this JOB, release the prohibition.
(3)If the error occurs again, delete the JOB where the alarm oc- curred.
(4)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(5)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  9An attempt was made to change the con- tents for the JOB pro- hibited from being edited.Setting error(1) Check the following settings.
∙Setting of EDIT LOCK in JOB header screen
If the JOB is protected from editing, release the prohibition.
    Software operation error occurred(1) Reset the alarm.
(2)If you edit this JOB, release the prohibition.
(3)If the error occurs again, delete the JOB where the alarm oc- curred.
(4)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(5)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  10An error occurred in JOB data control sys- tem.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  11An error occurred in sequence number of the accessed JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  12An error occurred in step number of the accessed JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  13A JOB specified at JOB search did not exist in the memory.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  14There was an instruc- tion that did not exist in a JOB because of inconsistency of the system software.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  16Unused handles were lacking when an at- tempt was made to open a JOB.Setting error(1) Check the following settings.
∙The number of call JOB stacks
Set the JOB configuration that decreases the number of call JOB stacks.
    Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  18The number of in- structions added to a JOB exceeded 9999.Setting error(1) Check the following settings.
∙The number of steps in JOB
Delete unnecessary instructions in JOB and add new instructions.
    Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  19The number of steps added to a JOB ex- ceeded 9999.Setting error(1) Check the following settings.
∙The number of steps in JOB
Delete unnecessary steps in JOB and add new steps.
    Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  20A JOB was newly cre- ated with the same name of the unde- fined JOB already specified in the mem- ory.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  22Failed to expand JOB information during the access to a JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  23The accessed JOB was not opened.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  24An error occurred in the cluster control process of the ac- cessed JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  25An error occurred when reading the cluster information of the accessed JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  26Failed to acquire the necessary memory area during the ac- cess to a JOB.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  27An attempt was made to change the con- tents for the line pro- hibited from being edited or the com- mented-out line.Setting error(1) Reset the alarm.
(2) Cancel the LINE EDIT LOCK/COMMENT OUT settings of tar- get lines in JOB CONTENTS screen.
    Software operation error occurred(1) Reset the alarm.
(2) Cancel the LINE EDIT LOCK/COMMENT OUT settings of tar- get lines in JOB CONTENTS screen.
(3) If the error occurs again, delete the line where the alarm oc- curred.
(4) If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(5) If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  28A false change in the marker JOB was at- tempted.Software operation error occurred(1) Reset the alarm.
(2) If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(3) If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  90The configuration in- formation for JOB data control is dam- aged.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  91The FAT information for JOB data is dam- aged.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  92A JOB data was de- stroyed.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  99A JOB data in the memory was de- stroyed.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4203SYSTEM ERROR (POSITION DATA)-1The memory area for position data is lack- ing at the initialization of the position data control process.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -2The number of axes for all the control groups is zero at the initialization of the po- sition data control process.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -3The number of axes for position data is ze- ro.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -4The number of stored position data exceed- ed the maximum stored data at the ini- tialization of the posi- tion data control process.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -5The memory size of the position data ex- ceeded the maximum memory size at the initialization of the po- sition data control process.Software operation error occurredReset the alarm, and then try again.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -6Unused position data file is destroyed.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -7Unused position data file does not exist.Software operation error occurredReset the alarm, and then try again.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -8Position data file is destroyed.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -9Position data control information is de- stroyed.Software operation error occurredReset the alarm, and then try again.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -10An error occurred in specified position data number.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -11Position data is not registered.Software operation error occurredReset the alarm, and then try again.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -12An attempt was made to access the unde- fined position data.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -13An attempt was made to access the position data for the undefined control group.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -14Position data control is not initialized.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -15The number of axes for the control groups exceeded the limit.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -16An error occurred in exclusive control during the position data control process.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -17An error occurred in exceptional control during the position data control process.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -20Inconsistency of data.Software operation error occurredReset the alarm, and then try again.
    YIF01 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    YCP21 board failure(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4204SYSTEM ERROR (POSITION DATA)1The number of axes for all the control groups is zero at the initialization of the po- sition data control processSoftware operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2The number of axes for all the control groups is zero at the initialization of the po- sition data control processSoftware operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3The number of axes for position data is ze- ro.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4The number of stored position data exceed- ed the maximum stored data at the ini- tialization of the posi- tion data control process.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5The memory size of the position data ex- ceeded the maximum memory size at the initialization of the po- sition data control process.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  6Unused position data file is destroyed.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  7Unused position data file does not exist.Setting error(1) Check the following settings.
∙The number of steps in JOB (position data)
Delete unnecessary position data in JOB and add new position data.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  8Position data file is destroyed.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  9Position data control information is de- stroyed.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  10An error occurred in specified position data number.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  11Position data is not registered.Setting error(1) Check the following settings.
∙Teaching of alarm occurred point Teaching the point where alarm occurred.
    Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  12An attempt was made to access the unde- fined position data.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  13An attempt was made to access the position data for the undefined control group.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  14Position data control is not initialized.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  15The number of axes for the control groups exceeded the limit.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  16An error occurred in exclusive control during the position data control process.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  17An error occurred in exceptional control during the position data control process.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  20Undefined position exists.Software operation error occurred(1) Reset the alarm.
(2)If the error occurs again, delete the JOB where the alarm oc- curred.
(3)If the error occurs again after the previous measures were ex- ecuted, initialize the JOB file in the MAINTENANCE mode, and then load the saved JOB file.
(4)If the error occurs again though the previous measures were executed, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4206SYSTEM ERROR (TRANSMISSION) SUB-Code 1 to 4: Sig- nifies the internal soft- ware error during data transmission.Software operation error occurred(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4207SYSTEM ERROR (MOTION)1An interrupt unde- fined in the main com- mand from the system control sec- tion occurred.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2An interrupt unde- fined in the sub com- mand from the system control sec- tion occurred.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  3The interrupt com- mand that was sent previously from the system control sec- tion is being pro- cessed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  4An error was detected in the interrupt com- mand data from the system control sec- tion.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5An undefined com- mand was detected in the sub segment task of MOTION section.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  6An undefined com- mand was detected in the SERVO-related processing of MO- TION section.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7An undefined com- mand was detected in the offline processing task of MOTION sec- tion.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  8An undefined com- mand was detected in the utility task of MO- TION section.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  10Task Token is not generated.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  11Mail-box Token is not generated.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  12Semaphore Token is not generated.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  14RMS receiving data errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  15RMS sending data er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  16RMS receiving unit errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  18Task generation errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  19Mail-box generation errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  20Semaphore genera- tion errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  22TCB area overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  23Stack area overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  24Mail-box area over- flowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  25Semaphore area overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  30Interrupt main com- mand errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  33Incorrect control group designationSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  34Offline bank sema- phore reception errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  35m_gen_area sema- phore reception errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  36Offline HA processing timeoutSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  37DM_BANK flag error (DM_BANK conver- sion processing)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  38S -> M offline pro- cessing command type errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  39Function specification error in the data trans- mission to the sensor boardSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  40Error in designation of application in the re- quest of general-pur- pose data preset for each application.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  45Mail-box of sequence task is not ready.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  46Control-group usage undefinedSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  47Segment task polling command errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  48Physical axis number errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  49The control group im- possible to release the brakeSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  50Sub-segment re- quest FULLSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  51Sub-segment pro- cess timeoutSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  52Data latch request FULLSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  53Data latch process timeoutSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  54AXIS command re- quest FULLSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  55AXIS command pro- cess timeoutSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  56Positioning monitor request FULLSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  57Positioning monitor process timeoutSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  58Failed AXIS SERVO OFF command re- quest during catego- ry1 emergency stopSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  59AXIS SERVO OFF
command execution system not set during category1 emergency stop
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  61Conversion primary expression for Power Source command <-> EW command not preparedSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  62Duplicated request error during master control-group trackingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  63GVM shared re- source semaphore errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  64JOB queue DEQUE errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  65Conversion primary expression for paint- ing device command
<-> EW command not prepared
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  66Execution system de- cision table not setSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  67Unknown mode data (Without TEACH/ PLAY mode data)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  68Shift-value output tim- eout of the general- purpose sensorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  69Interrupt main status setSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  71System number error at the master side in twin synchronous systemSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  72No data link added to the commandSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  73Setting status error of the user coordinates fileSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  75Previous path data reference errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  76Target position preparation error in arc-retry shift motion modeSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  79Inner track zone sta- tus errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  80Instruction queue and instruction system data area overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  81Offline answer bank flag errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  82Path and trace queue ENQUE BANK errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  83Pending and block end request FULLSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  84Base axis file type er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  85Output buffer SY- SCON for automatic test data in useSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  86Conversion comple- tion status for AXIS section feedback latch data not estab- lishedSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  88File C1 through C3 for calibration between robots not setSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  89File C1 through C3 for conveyor calibration not setSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  90HA function error (conv_pos_data())Setting error(1) Check the following settings.
∙Correct the JOB so that the target position data is within the mo- tion range.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  91HA function error (conv_shift_data())Setting error(1) Check the following settings.
∙Correct the JOB so that the target position data is within the mo- tion range.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  94HA function error (conv_pulse_to_an- gle())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  95HA function error (pr_atinf_pos_- make())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  97HA function error (get_gun_ctrl_ori_an- gle())Software operation error occurred(1) Reset the alarm, and then try again.
(3) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  98HA function error (make_conv_frm_da- ta())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  99HA function error (cal- c_dist_pos())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  100Control-group axis configuration informa- tion parameter errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  101Error in the parameter for the table for physi- cal axesSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  102Error in the parameter for the table for physi- cal TUSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  103Excessive number of control group axes in useSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  104JOG and PLAY maxi- mum speed setting parameter errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  105Reduction ratio set- ting parameter errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  106Feedback PPR set- ting parameter errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  121JOB argument stack overflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  122JOB argument stack underflowSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  123Designation error of the fetched feedback pulse area at prepara- tion of current valueSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  128Timeout for waiting permission to modify the number of averag- ing timesSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  129Object undefined for CLEAR instructionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  130No space in RT_BANK setting area for correction- amount dataSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  131Queue operation er- ror for variable write- in history at preread- ing (at ENQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  132Queue operation er- ror for variable write- in history at preread- ing (at DEQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  133Queue operation er- ror for variable write- in history at preread- ing (undefined opera- tion)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  134Queue operation er- ror for variable write- in history at preread- ing (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  135Queue operation er- ror for score-board setting history (at EN- QUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  136Queue operation er- ror for score-board setting history (at DE- QUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  137Queue operation er- ror for score-board setting history (unde- fined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  138Queue operation er- ror for score-board setting history (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  139Queue operation er- ror for instruction exe- cution (at ENQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  140Queue operation er- ror for instruction exe- cution (at DEQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  141Queue operation er- ror for instruction exe- cution (undefined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  142Queue operation er- ror for instruction exe- cution (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  143Queue operation er- ror for WORK ID con- veyor (at ENQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  144Queue operation er- ror for WORK ID con- veyor (at DEQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  145Queue operation er- ror for WORK ID con- veyor (undefined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  146Queue operation er- ror for WORK ID con- veyor (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  147Queue operation er- ror for WORK IN/OUT checking conveyor (at ENQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  148Queue operation er- ror for WORK IN/OUT checking conveyor (at DEQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  149Queue operation er- ror for WORK IN/OUT checking conveyor (undefined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  150Queue operation er- ror for WORK IN/OUT checking conveyor (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  151Queue operation er- ror for waiting for semaphore for LOCK instruction (at EN- QUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  152Queue operation er- ror for waiting for semaphore for LOCK instruction (at DE- QUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  153Queue operation er- ror for waiting for semaphore for LOCK instruction (unde- fined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  161Functional safety command request is full.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  162Functional safety command request is latency over.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  154Queue operation er- ror for waiting for semaphore for LOCK instruction (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  221Transfer data over- flow in offline data bankSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  222Impossible to execute system exclusive for system JOBSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  223Event queue number range exceededSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  224No motor-gun control group for ESRCH in- structionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  225The number of WORK ID data and the MAX. WORK FIND COUNT un-
matched (MOTION ≠
CV)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  226The number of WORK IN/OUT data and the MAX. WORK FIND COUNT un-
matched (MOTION ≠
CV)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  227Excessive number of scheduling for execu- tion of instructionsSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  228Instruction execution scheduling impossi- bleSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  229Illegal 1st-line move instruction at execu- tion of +SMOV in- structionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  230Impossible to execute the slave circular in- terpolation and the master circular inter- polation at the same timeSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  231Impossible to execute the slave spline inter- polation and the mas- ter spline interpolation at the same timeSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  232Illegal index value for a +MOVx instructionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  233No xth-line move in- struction exists where the master control group belongs.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  234Marking error for WORK ID conveyor queue (empty queue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  235Marking error for WORK IN/OUT con-
veyor queue (empty queue)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  236Data error 1 at restart- ing after an emergen- cy stop (actual status and the data status unmatched)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  237Data error 2 at restart- ing after an emergen- cy stop (actual status and the data status unmatched)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  238Data error 3 at restart- ing after an emergen- cy stop (actual status and the data status unmatched)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  239Timeout for receiving segment data output requestSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  240The number which designates the setting area of correction amount in RT_BANK exceeded the limit value.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  241Task error of the func- tion calling source (cv_sync_intr ( ))Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  242No control group for motor gun for clear- ance move instructionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  243Motor gun condition file number error (in- cluding gun pressure file)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  244GETTOOLW robot designation errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  245Overflow of entry number for instruction executionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  246Data latch processing (function number overflow)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  247Data latch processing (real-time status num- ber overflow)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  248Failed to set a timer unit. (No allocation space for timer unit setting)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  249Segment data miss- ing (seg_t_req was not received in time.)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  250GETS instruction in- ternal errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  251SETFILE undefined fileSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  252GETFILE undefined fileSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  253The parameter was destroyed when a GETPRM instruction was executed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  254Null pointer assign- ment detectedSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  255Function or other pro- cessing parameter er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  260Arithmetic answer is not set at prereading (ADV_HA_ANS.flag
== OFF)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  261Heap area obtain- ment failure (A_BANK)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  262Heap area obtain- ment failure (C_BANK)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  263Heap area obtain- ment failure (Instruc- tion queue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  264Heap area obtain- ment failure (Path/ trace queue)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  265Heap area obtain- ment failure (IFEx- press descriptor)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  279Specified MSS sys- tem instance is not generated.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  280API error (HDAS_get_alias_na me())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  284GA generation num- ber is over the limit.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  285GA gene number is over the limit.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  286GA initial generation number setting errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  287GA control group er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  288Learning control anal- ysis errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  290HA function error (get_svspot_ntch_da- ta())Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  291Paint instruction inter- nal errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  292Paint recover control error (Paint Gun pa- rameter error)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  293Paint recover control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  294JOB completion time overSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  295SERVO simulator av- eraging time change errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  310Synchronized queue operation error for WORK ID conveyor (at ENQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  311Synchronized queue operation error for WORK ID conveyor (at DEQUE)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  312Synchronized queue operation error for WORK ID conveyor (undefined operation)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  313Synchronized queue operation error for WORK ID conveyor (data length too long)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  314Synchronized queue operation error for WORK IN/OUT
checking conveyor (at ENQUE)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  315Synchronized queue operation error for WORK IN/OUT
checking conveyor (at DEQUE)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  316Synchronized queue operation error for WORK IN/OUT
checking conveyor (undefined operation)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  317Synchronized queue operation error for WORK IN/OUT
checking conveyor (data length too long)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  318Synchronized queue operation error for WORK ID conveyor or WORK IN/OUT
conveyor (atDEQUE)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  319Synchronized queue empty error for WORK ID conveyor (at execution of CVQUESoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  320Synchronized queue empty error for WORK IN/OUT con-
veyor (at execution of CVQUE)
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  330P-PLC suspend errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  331P-PLC suspend errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  332P-PLC suspend seq errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  333P-PLC suspend seq no errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  334P-PLC suspend seq no errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  340PSTRIG suspend errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  341PSTRIG suspend errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  342PSTRIG suspend seq errSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  500SL undefined inter- rupt command (main command)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  501SL undefined inter- rupt command (sub command)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  502Previous SL interrupt command processingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  503SL interrupt com- mand data errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  999Arithmetic section er- ror (segment data all zero timeout)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1000System clock (RTC) setting errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1001System task priority arrangement errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1002VxWorks primitive er- ror (msgQCreate)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1003VxWorks primitive er- ror (msgQSend)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1005VxWorks primitive er- ror (semBCreate)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1007VxWorks primitive er- ror (semTake)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  1008VxWorks primitive er- ror (msgQSend) Mes- sage queue is full.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  1100Failed system JOB environment configu- rationSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  2000Failed system JOB environment configu- rationSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4208SYSTEM ERROR (ARITH)1Prereading task is not completed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  5The averaging buffer in the arithmetic sec- tion is destroyed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  6No previous bank ex- ists.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  7The answer bank flag is ON.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  8An error occurred in preparation of current position.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  9Mails could not cor- rectly be received in the current task.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  10Spline-curve path designation errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  11The previous bank’s prereading conver- sion could not correct- ly be completed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  12A robot designation error occurred at JOG operation using the external reference point.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  13Designation error of cubic interference co- ordinatesSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  14Path control position data error of preread- ing bankSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  16Station/base axis mo- tion command errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  18User coordinates number errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  19Processing error in
re-preparation of seg- ment control data
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  20Prereading task not completed at master in twin synchronous systemSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  23Dynamic model arith- metic errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  24Speed limit control er- ror (excessive mo- ment of gravity)Setting error(1) Check the following settings.
∙The allowable breaking torque was exceeded only by the gravity moment. Set the gravity value of the tool within payload of the ro- bot.
∙Teach the robot orientation that does not become the overload for each-axes of the robot.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  25Square root of a neg- ative numberSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  26The system number is not set at master in twin synchronous system.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  29FORMCUT internal control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  30Arm interference check error (radius data referencing mis- take)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  31Arm interference check error (miscal- culation using direct kinematics)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  32Arm interference check error (L-axis expansion flag setting error)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  33Arm interference check error (check- point re-setting error)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  34Impossible to edit the averaging buffer (zero division)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  35No master-group is designated at prepa- ration of master-tool user coordinates.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  37Gauging function er- ror (command desig- nation error)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  38A coordinated motion was attempted using the Following func- tion.Setting error(1) Check the following settings.
∙Change the setting so that only the robot moves.
∙The coordinated motion cannot be performed by the Following function.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  39Zero or a negative value is set for the bending speed of the Following function.Setting error(1) Check the following settings.
∙Set a positive value for the bending speed.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  40Zero or a negative value is set for the bending stroke of the Following function.Setting error(1) Check the following settings.
∙Set a positive value for the bending stroke.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  41Pulse linked JOG function errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  42Special JOG opera- tion errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  44Segment over less: Segment excessive errorSetting error(1) Check the following settings.
∙The teaching position cannot hold down the speed by the seg- ment over less function. Reduce the teaching speed of the JOB.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  45Segment over less: Path calculation re- peat errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  47Play path control: ini- tialization errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  48Play path control: continue process er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  49Play path control: Step continuous ini- tialization errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  50Play path control: step continuous mo- tion execution pro- cess errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  54Approximation model internal control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  55Pair coordinate sys- tem position calcula- tion function errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  56OPT higher accelera- tion and deceleration control is not allowed when Function accel- eration and decelera- tion control is enabled.Setting error(1) Check the following settings.
∙OPT higher acceleration and deceleration control is used.
∙Don’t use the OPT higher acceleration and deceleration control.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  57Arithmetic error oc- curred when calculat- ing the acceleration and deceleration time (Function accelera- tion and deceleration control)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  58Arithmetic error oc- curred when recalcu- lating the acceleration and deceleration time (Function accelera- tion and deceleration control)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  59Arithmetic error oc- curred when calculat- ing PL control (Function accelera- tion and deceleration control)Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  60Arithmetic error oc- curred when calculat- ing Function acceleration and de- celeration dry run.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  61Arithmetic error oc- curred when calculat- ing current path of continuous motion stop operationSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  62Arithmetic error oc- curred when calculat- ing next path of continuous motion stop operationSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  63Arithmetic error oc- curred when calculat- ing acceleration time when continuous mo- tion in the prereading processingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  64Arithmetic error oc- curred when calculat- ing deceleration time when continuous mo- tion in the prereading processingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  65Arithmetic error oc- curred when calculat- ing acceleration and deceleration time when teaching.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  66Arithmetic error oc- curred when calculat- ing acceleration and deceleration time for plucking in preread- ing processing 1Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  67Arithmetic error oc- curred when calculat- ing acceleration and deceleration time for plucking in preread- ing processing 2Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  68Arithmetic error oc- curred when calculat- ing acceleration and deceleration time for plucking in preread- ing processing 3Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  69Arithmetic error oc- curred when calculat- ing acceleration and deceleration time for plucking in preread- ing processing 4Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  70Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control plucking in prereading process- ing 1Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  71Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control plucking in prereading process- ing 2Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  72Arithmetic error oc- curred when calculat- ing acceleration and deceleration for pluckingSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  73Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control in prereading processing 1Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  74Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control in prereading processing 2Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  75Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control in prereading processing 3Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  76Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control in prereading processing 4Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  77Arithmetic error oc- curred when calculat- ing acceleration and deceleration for PL control in prereading processing 5Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  96Press full synchro- nous function: Press synchronous execu- tion errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  97Press full synchro- nous function: The press position carried out cycle movement over.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  98Press full synchro- nous function: Press synchronous position errorSoftware operation error occurred(1)Execute Position Adjustment Function to correct the position gap between press position and the robot.
∙Confirm that both press and robot are maintained in stopped state.
∙Change the specific input: Position Correct Request (#40540) to ON.
∙Execute the Press synchronization JOB again.
∙Wait for the specific output „Correcting position(#50683)“ to be- come OFF and then start up the press.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  99Press full synchro- nous function: Posi- tion search errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  102Posture control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  105Timing control func- tion control group er- rorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  106Feedback approxima- tion model table queue control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  107Feedback approxima- tion model data refer- ence errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  65535For HA debug useSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4209OFFLINE SYSTEM ERROR (ARITH)100Data setting error in offline data bankSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  101Data setting error in offline answer bankSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  102OFF_USER_POS oc-
cupation control error
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  103OFF_USER_POS
valid control error
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  104Mail-receiving error of offline taskSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  105Offline occupation control errorSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  107OFF_USER_ROT_-
POS occupation con- trol error
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  108OFF_USER_ROT_-
POS valid control er- ror
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  109OFF_CV_CALIB_-
POS occupation con- trol error
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  110OFF_CV_CALIB_-
POS valid control er- ror
Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  111Incorrect teaching for offline conveyor track- ing turntable functionSoftware operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  112No robot is designat- ed for offline conveyor tracking turntable function.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4210SYSTEM ERROR (LOCAL VARI- ABLE)-1Local variable is not used.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -2Memory area for local variable could not be obtained.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -3No unused handle value exists when lo- cal variable area is created.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -4An error occurred in exclusive control.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -5Handle value is inval- id for specified local variable.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -6Handle value is incor- rect for specified local variable.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -7An error occurred when memory area for local variable was released.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -8An error occurred when memory area for local variable was registered.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -9Local variable control process is not initial- ized.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -10Local variable area shared heap area.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -11An error occurred in exclusive control.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -12An error occurred in exclusive control when control of the lo- cal variable was pro- cessed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4220SERVO power OFF FOR JOB SUB-Code: Control groupSetting error(1) Check the following settings.
∙Turn OFF the SERVO power supply, and then turn ON the SER- VO power supply for the group axis to be operated.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4221SERVO power OFF FOR JOB SUB-Code: Control groupThe SERVO power is not supplied.∙Turn OFF the SERVO power supply, and then turn ON the SER- VO power supply for the group axis to be operated.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4224MEMOPLAY FILE ERROR-1An error occurred in control process for memory play file.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -2The arrangement ad- dress information is destroyed for memory play file system.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -3The fixed control in- formation is de- stroyed for memory play file system.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -4The fixed control in- formation is de- stroyed for memory play file system.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -5An attempt was made to newly register the memory play file un- der use.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -6An error occurred in checking written sam- pling data when the data was written to CMOS.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -7An attempt was made to access an unused memory play file data.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -8The memory play file is destroyed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -9The memory area for sampling data is full.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -10The sampling data is destroyed.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -11Data in control pro- cess for memory play file is incorrect.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -12The sampling data is scanned only at top or end position.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -13The memory play file system is not initial- ized.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -14The offset value is out of range at sampling data scanning.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4225OVER SPEED (YCP21) Signifies the control axis number which detected an errorSetting error(1) Check the following settings.
∙The gun tip hits the welded target distance of motor gun
∙robot motion (external force, gravity)
    Connection failure(1) Reset the alarm.
(2) If the alarm occurs again, check the connection and inserting state of the following cables and connectors.
∙The motor power line
∙The encoder line
    Module failure (mo- tor)(1) Reset the alarm.
(2) If the alarm occurs again, replace the following unit.
∙The motor
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4226COMMUNICATION SERVICE ERROR1The communication channel could not be opened/closed at OPEN/CLOSE in-
struction execution.
Setting error(1) Check the following settings.
∙Setting of the RS (transmission) parameter
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  100The communication port is already opened.Setting error(1) Check the following settings. The serial port setting
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  101The communication port is not opened.Setting error(1) Check the following settings. The serial port setting
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  102No space was found in data sent buffer.Setting error(1) Check the following settings. The serial port setting
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  103The setting value for the event queue des- ignation parameter is incorrect.Setting error(1) Reset the alarm.
(2)Check the following settings.
∙RS157…Set to 1 to 4
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  105The type of output data is incorrect.Setting error(1) Reset the alarm.
(2)Check the following settings. The serial port setting
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4228WRONG DATA  Software operation error occurred(1) Reset the alarm, and then execute following operation.
∙Select a sub menu [WRONG DATA LOG] under main menu [SETUP].
∙Execute “RESTORE” by selecting “UTILITY” from the pull-down menu.
*Occurrence date changes to restoration date after it is restored.
∙Turn the power OFF and then ON to check the factor of the in- consistency 1 and 2, on the data inconsistency screen in MAIN- TENANCE mode.
The factor 1: Check the position of the corresponding file The factor 2: Register the position of the corresponding file
again
*The factor 3:Just turn the power OFF and then ON again.
(2)If it would not restore, select “RE CHECK” from the pull-down menu.
(3) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Data error(1) If different axes configuration data is loaded, the system data becomes incorrect status, which causes this alarm. In this case, execute the following operations.
∙Select a sub menu [WRONG DATA LOG] under main menu [SETUP].
∙Select “UTILITY” from the pull-down menu to execute “RE- STORE”.
∙Load correct axes configuration data
(2)If it would not restore, select “RE CHECK” from the pull-down menu, and then load correct axes configuration data.
(3) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4229ETHERNET PRO- CESS ERROR1An error occurred in the acquisition pro- cess of the IP address during the IP address monitoring process of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2An error occurred in the acquisition pro- cess of subnet mask during the network service data creation process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3An error occurred in the acquisition pro- cess of gateway during the network service data creation process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4An error occurred in the conversion pro- cess of gateway ad- dress during the network service data creation process of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5An error occurred in the conversion pro- cess of DNS server address during the network service data creation process of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6An error occurred in the acquisition pro- cess of domain during the network service data creation process of the Ethernet func- tion.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7An error occurred in the acquisition pro- cess of SNTP server during the network service data creation process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8An error occurred in the acquisition pro- cess of host name during the network service data creation process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  9An error occurred in the newest DNS infor- mation getting pro- cess from DHCP server in the DNS process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  10An error occurred in the setting process to update DNS informa- tion in the DNS pro- cess of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  11An error occurred in the setting clearing process to update DNS information in the DNS process of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  20The subnet mask was not able to be ac- quired in the DHCP information update process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  21Subnet mask update error occurred in the DHCP information update process of the Ethernet function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  25Gateway update error occurred in the DHCP information update process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  26Gateway clear error occurred in the DHCP information update process of the Ether- net function.Setting error(1) Check the following settings.
∙The DHCP server operation (If the DHCP is used)
∙The network status (If the DHCP is used)
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then insert the CF card which inserted original YCP21 board into the new YCP21 board.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  35IP address duplica- tion was detected.Setting error(1)Check the following settings.
·IP address setting of network in MAINTENANCE mode
·IP addresses of other devices in the network.
    Software operation error occurred(1)Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board.
  36IP address duplica- tion was detected.Setting error(1)Check the following settings.
·IP address setting of network in MAINTENANCE mode
·IP addresses of other devices in the network.
    Software operation error occurred(1)Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board.
  40IP address can not be gotten or can not be updated via DHCP.Setting error(1)Check the following settings and status.
·The DHCP server operation (If the DHCP is used)
·The network status (If the DHCP is used)
    Software operation error occurred(1)Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  50Gateway setting is faulted.Software operation error occurred(1)Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
    YCP21 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YCP21 board. Save the CMOS.BIN before replace the board to be safe. Replace the YCP21 board, and then remove the CF from the failure YCP21 board to insert it into the new YCP21 board.
4234COMMUNICATION TIMEOUT
(IO MODULE)
0The IO module board connected with 0th serial bus exists.Software operation error occurred(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
  1An error was detected in communications timeout with the I/O module board con- nected with 1st serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The M ǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2An error was detected in communications timeout with the I/O module board con- nected with 2nd serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The M ǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3An error was detected in communications timeout with the I/O module board con- nected with 3rd serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4An error was detected in communications timeout with the I/O module board con- nected with 4th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The M ǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5An error was detected in communications timeout with the I/O module board con- nected with 5th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6An error was detected in communications timeout with the I/O module board con- nected with 6th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The M ll communications cable which I/O module of the corre- sponding node number
∙(In case of M ll communications last station) Terminator
∙24V power of the corresponding I/O module
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7An error was detected in communications timeout with the I/O module board con- nected with 7th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8An error was detected in communications timeout with the I/O module board con- nected with 8th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  9An error was detected in communications timeout with the I/O module board con- nected with 9th serial bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  10An error was detected in communications timeout with the I/O module board con- nected with 10th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  11An error was detected in communications timeout with the I/O module board con- nected with 11th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  12An error was detected in communications timeout with the I/O module board con- nected with 12th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  13An error was detected in communications timeout with the I/O module board con- nected with 13th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  14An error was detected in communications timeout with the I/O module board con- nected with 14th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
·M II communications cable (CN114) of the YIF01 board
·M II communications cable (CN300) of the YIU unit
·(In case of M II communications last station) Terminator
·24V power of the YIU unit
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  15An error was detected in communications timeout with the I/O module board con- nected with 15th seri- al bus when the control power turned ON.Setting error(1) Check the following settings.
∙The rotary switch setting which specifies slot numbers of each I/ O module
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following cables and connectors.
∙The Mǁ communications cable which I/O module of the corre- sponding node number
∙(In case of Mǁ communications last station) Terminator
∙24V power of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  16An error was detected in communications timeout with the I/O module board con- nected with 1st PCI connector when the control power turned ON.Setting error(1) Check the following settings.
∙PCI slot number in which each PCI board is mounted
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following connector.
∙The PCI connector of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
∙The corresponding I/O module (PCI board)
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  17An error was detected in communications with the I/O module board connected with 2nd PCI when the control power turned ON.Setting error(1) Check the following settings.
∙PCI slot number in which each PCI board is mounted
∙I/O module settings in MAINTENANCE mode
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following connector.
∙The PCI connector of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
∙The corresponding I/O module (PCI board)
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  18An error was detected in communications timeout with the I/O module board con- nected with 3rd PCI when the control pow- er turned ON.Setting error(1) Check the following settings.
∙PCI slot number in which each PCI board is mounted
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following connector.
∙The PCI connector of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
∙The corresponding I/O module (PCI board)
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  19An error was detected in communications timeout with the I/O module board con- nected with 4th PCI when the control pow- er turned ON.Setting error(1) Check the following settings.
∙PCI slot number in which each PCI board is mounted
∙I/O module settings in MAINTENANCE mode
    Connection failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, check the connection and insertion of the following connector.
∙The PCI connector of the corresponding I/O module
    I/O module failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the following board. Save the CMOS.BIN before replace the board to be safe.
∙The corresponding I/O module (PCI board)
    YIF01 board failure(1) Turn the power OFF then back ON.
(2) If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN before replace the board to be safe. Replace the YIF01 board, and then load the CMOS.BIN saved before alarm occurred.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4236SPOT WELDER ERROR (NADEX)-20NADEX I/F board un- connected.Setting error(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, check the connection with the NA- DEX I/F board(XFB01B-2 board).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -21JL012 access time out.Communication error(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, check the connection and inserting state of the following cable.
∙The communications cable for the I/O module
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -22JL012 data setting er- ror.Communication error(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, check the connection and inserting state of the following cable.
∙The communications cable for the I/O module
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -23DeviceNet response error.Communication error(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, check the connection and inserting state of the following cable.
∙The communications cable for the DeviceNet
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -24NADEX data sheet format error.Software operation error occurredThe connected NADEX spot welder isn’t corresponded to.Save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  -25JL012 data overflow.Communication error(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, check the connection and inserting state of the following cable.
∙The communications cable for the I/O module
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -100Initialization error.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -102Not found the spot welder number.Setting errorCheck the following settings.
∙The parameter “AxP003:The maximum number of connected spot welders”.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  -111ASW file size over.Software operation error occurredThe connected NADEX spot welder isn’t corresponded to.Save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
  -117System call error.Software operation error occurred(1) Reset the alarm, and then try again.
(2) If the alarm occurs again, save the CMOS.BIN in MAINTE- NANCE mode, and then contact your YASKAWA representative about occurrence status (operating procedure).
4240TPS:ERROR SUB-Code: Welding power source num- ber.Error occurred in the Fronius power source.Confirm the following content.
Step1: Check what kind of the error code is expressed on the front panel of Fronius power source.
Step2: Check according with the Fronius’s manual.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
4241MOTOWELD SYS- TEM RESET1Error from welder 1.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  7Error from welder 7.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  302SUB-Code: Error No. from welder.Arc welding power source errorWhen finish system reset, Shut down the welding power source.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4242MOTOWELD IN- PUT OVER-CUR- RENT1Error from welder 1.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  2Error from welder 2.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  3Error from welder 3.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  4Error from welder 4.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  6Error from welder 6.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  7Error from welder 7.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  8Error from welder 8.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
  107SUB-Code: Error No. from welder.Arc welding power source error(1) Check if the output cable is short-circuited or grounded.
(2) The power circuit may be broken. Contact your YASKAWA representative.
4243MOTOWELD OUT- PUT OVER-CUR- RENT1Error from welder 1.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  2Error from welder 2.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Error from welder 6.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  701SUB-Code: Error No. from welder.Arc welding power source errorConfirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2) Check that the contact tip does not contact the welding work piece.
(3) Check that the encoder cable is not damaged.
(4) Check if the screws of the connector terminal block are se- curely fastened. If the encoder cable is disconnected or the screws are loosened, the wire feeding speed becomes excessive- ly fast and an error occurs in the wire feeding amount. Replace the encoder cable or fasten the screws of the connector terminal block.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4244MOTOWELD IN- PUT OVER-VOLT- AGE1Error from welder 1.Arc welding power source errorConfirm the input voltage.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorConfirm the input voltage.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4245MOTOWELD EX- CESSIVE TEM- PERATURE1Error from welder 1.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  4Error from welder 4.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  8Error from welder 8.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  102The temperature in the primary control circuit exceeds the specified value of the welding source.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.410).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  103The temperature in the secondary control circuit exceeds the specified value of the welding source.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard (Item No.318).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  105The temperature in the DC reactor ex- ceeds the specified value of the welding source.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)In case of RL350, Check the thermal guard of DCL2 (Item No.312).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  340The temperature in the Main board Pr (MB) exceeds the specified value of the welding source.Arc welding power source error(1)Check the ambient temperature (40 degrees centigrade or less) and operational ratio (60%).
(2) Check if there are dust, dirt, and clogging on the dust protec- tive filter. Clean or replace the dust protective filter if necessary.
(3)Replace the Main board Pr (MB)-030(Item No. 504).
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4246MOTOWELD IN- PUT UNDER-VOLT- AGE1Error from welder 1.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the input voltage.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the input voltage.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4247MOTOWELD WA- TER UNDER-FLOW1Error from welder 1.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  703SUB-Code: Error No. from welder.Arc welding power source error(1)Fill up the cooling water.
(2)Check the circuit of cooling water.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4248MOTOWELD DIGI- TAL I/F WDG.ER- ROR1Error from welder 1.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  3Error from welder 3.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  5Error from welder 5.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  6Error from welder 6.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  401SUB-Code: Error No. from welder.Arc welding power source errorConfirm the following content.
(1) The LAN cable has not damaged.
(2) The Ethernet protocol address setting is correct.
(Check that C parameter of the welding power source and RS pa- rameter of the robot controller.)
(3) Welding power source is turn on.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
4249MOTOWELD DIGI- TAL I/F NODE ER- ROR1Error from welder 1.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  2Error from welder 2.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  3Error from welder 3.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  4Error from welder 4.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
Alarm No.Alarm NameSUB-
Code
MeaningCauseRemedy
  5Error from welder 5.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  6Error from welder 6.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  7Error from welder 7.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  8Error from welder 8.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).
  402SUB-Code: Error No. from welder.Arc welding power source errorCheck the Node of the each welder power sources and robot con- troller.
    otherIf the alarm occurs again, save the CMOS.BIN in MAINTENANCE mode, and then contact your YASKAWA representative about oc- currence status (operating procedure).